Download PDF
Original Article  |  Open Access  |  28 Mar 2024

Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles

Views: 933 |  Downloads: 201 |  Cited:  1
Extracell Vesicles Circ Nucleic Acids 2024;5:138-64.
10.20517/evcna.2023.77 |  © The Author(s) 2024.
Author Information
Article Notes
Cite This Article

Abstract

Aim: The lung is the second most frequent site of metastatic dissemination. Early detection is key to improving survival. Given that the lung interfaces with the external environment, the collection of exhaled breath condensate (EBC) provides the opportunity to obtain biological material including exhaled miRNAs that originate from the lung.

Methods: In this proof-of-principal study, we used the highly metastatic MDA-MB-231 subline 3475 breast cancer cell line (LM-3475) to establish an orthotopic lung tumor-bearing mouse model and investigate non-invasive detection of lung tumors by analysis of exhaled miRNAs. We initially conducted miRNA NGS and qPCR validation analyses on condensates collected from unrestrained animals and identified significant miRNA expression differences between the condensates of lung tumor-bearing and control mice. To focus our purification of EBC and evaluate the origin of these differentially expressed miRNAs, we developed a system to collect EBC directly from the nose and mouth of our mice.

Results: Using nanoparticle distribution analyses, TEM, and ONi super-resolution nanoimaging, we determined that human tumor EVs could be increasingly detected in mouse EBC during the progression of secondary lung tumors. Using our customizable EV-CATCHER assay, we purified human tumor EVs from mouse EBC and demonstrated that the bulk of differentially expressed exhaled miRNAs originate from lung tumors, which could be detected by qPCR within 1 to 2 weeks after tail vein injection of the metastatic cells.

Conclusion: This study is the first of its kind and demonstrates that lung tumor EVs are exhaled in mice and provide non-invasive biomarkers for detection of lung tumors.

Keywords

Extracellular vesicles, exhaled breath condensate, orthotopic lung tumor-bearing animal model, miRNAs

INTRODUCTION

Lung cancer is the second leading cause of cancer incidence (2.1 million cases per year) and mortality (1.8 million deaths per year) globally[1,2]. However, the lung is also the second most frequent site of metastatic growth for extra-thoracic malignancies[3]. It is recognized that because of its role in blood circulation, the lung offers optimal conditions for the development of secondary cancers that arise from primary colorectal (~25.8%), head and neck (~19.4%), urologic (i.e., bladder, kidney, and testicular; ~14.7%), breast (~10.5%), melanoma (~6.5%), gynecological, blood, and other cancers (~6.1%)[4]. Currently, it is estimated that ~5%-10% of patients with malignant cancer will at some point develop pulmonary metastatic lesions that are either synchronous (i.e., found at the time of primary cancer diagnosis) or metachronous (i.e., found as a recurrent lesion or after primary cancer diagnosis)[5,6]. The 5-year survival rate for patients who develop secondary lung metastases is very low; for example, it is estimated at ~21% for patients initially diagnosed with primary breast cancer and < 10% for those initially diagnosed with primary colorectal cancer[7,8]. Clinically, the early detection of micro-metastases developing within the lung tissue is extremely difficult as early invading cells are disseminated and their physical detection by chest x-rays or computed tomography (CT) of the chest[9]. Although late detection of secondary lung cancer has a very poor prognosis, early radiation therapy, chemotherapy, and metastasectomy have been shown to significantly increase patient survival[10,11]. Therefore, for the optimal sequence and timing of local interventions, it is imperative to improve early detection of metastatic disease.

In order to improve the clinical detection of secondary lung cancers and to complement current imaging strategies, recent research efforts have led to the development of robust non-symptom-driven molecular screening assays. These assays have been designed to detect circulating primary tumor bioproducts such as circulating tumor cells (CTCs), circulating tumor DNA (ctDNA), circulating RNA transcripts (i.e., circular RNAs, messenger RNAs (mRNA), microRNAs (miRNA) and long non-coding RNAs), and more recently circulating tumor extracellular vesicles (EVs)[12-18]. Although the detection of CTCs has been used prognostically, it is not foolproof and a significant subset of patients who develop metastatic disease are not identified using this approach[19-22]. Although there are known biomarkers for the detection of specific cancers (e.g., AFP+CEA+CA125 for primary breast cancer or PSA for prostate cancer), there are currently no blood-based biomarker assays that can predict the development of secondary lung cancer[23]. Even though direct airway collection strategies [i.e., nasal epithelial brushing, sputum, bronchial brushing, bronchioalveolar lavage (BAL), and exhaled breath condensate (EBC)] are being investigated for the detection of primary lung cancer, they have not been evaluated for the detection of secondary lung cancer[24-32].

The growing field of breath biopsy (i.e., the collection and analysis of exhaled breath) is showing great promise for the detection of lung tumors[32-34]. Indeed, the analysis of volatile organic compounds (VOCs) (i.e., ammonia, nitric oxide, hydrogen sulfide, acetone, aldehyde, methane, ethane, propane, and carbon dioxide)[35,36] and non-volatile organic compounds (non-VOCs) (e.g., urea, amino-acids, RNA, DNA, proteins, lipids, surfactants) has been shown to reflect the metabolic and biologic repercussions of lung tumors[37,38]. Ongoing studies on VOCs are aimed at identifying metabolic changes associated with disease, whereas non-VOC studies are aimed at identifying and measuring biological compounds originating from tumor cells[39,40]. The collection of VOCs requires air-tight equipment for instant electronic analysis of exhaled gasses, whereas non-VOCs can be collected by the condensation of exhaled vapors to provide an exhaled breath condensate (EBC) biofluid, which can be stored and subsequently analyzed using different types of molecular assays (i.e., NGS, qPCR, methylation assays, etc.)[41,42]. Studies that have been conducted on EBC have revealed that it contains miRNAs, including those deregulated and released by tumors, with unique expression ratios that may be quantifiable and, in turn, allow detection of lung tumors[43-47]. Interestingly, recent investigations have also revealed that EBC contains extracellular vesicles (EVs), whose stably packaged miRNA cargoes can be analyzed and that may also help improve the detection of lung diseases[48-50].

It is well documented that miRNAs are involved in the regulation of all biological processes[51,52], and a large body of research has demonstrated that the deregulation of miRNA expression is associated with the initiation, development, and metastatic dissemination of human tumor cells[53-58]. Recent studies have also shown that miRNA profiles of tumor cells can provide both diagnostic and prognostic information on tumor progression[59-62]. Importantly, tumor cells can exchange miRNAs with both neighboring and distant cells via EVs. The molecular cargoes of tumor EVs, particularly miRNAs, have been shown to play important roles in the transcriptomic reprogramming of target cells[63-65]. For example, tumor EV miRNAs of breast, lung, and other types of human tumors have been associated with the modulation of angiogenesis[60,65], cellular proliferation[66-68], immune response[69,70], and the establishment of distal pre-metastatic niches[71-75].

EVs represent a large family of robust phospholipid bi-layered membrane-bound nanoparticles that are secreted by all human cells and can diffuse within tissues, circulate in the bloodstream, and be found in all biofluids[76,77]. EVs share common surface protein markers (i.e., CD9, CD81, CD83, Flotilin, etc.), as well as unique surface protein markers acquired from their cell of origin, which can be targeted by antibodies in molecular assays designed for their purification[78-83]. Studies of the miRNA content of circulating tumor EVs, specifically those purified from the circulation or those from other biofluids, have identified unique profiles, which can be associated with their tumor cells of origin[84]. Therefore, it is well perceived that the isolation of tumor EVs from biofluids, followed by the analysis of their miRNA cargos, has the potential to enable the development of non-invasive tumor detection assays for diagnostic and prognostic applications[85-91].

In this proof-of-principle study, we sought to explore the potential of utilizing exhaled miRNAs for non-invasive detection of secondary lung cancer in orthotopic animal models. For these analyses, we chose to inoculate a highly metastatic breast cancer cell line that has been well documented to rapidly establish significant pathological lung tumor burden in athymic nude mice, which provided an adequate model to test the collection and analysis of exhaled breath condensates[92-95].

MATERIALS AND METHODS

Cell culture

MDA-MB-231 subline 3475 triple-negative breast cancer cells were selected because of their aggressive and targeted lung tumor growth. MDA-MB-231 subline 3475 cells expressing both TdTomato-Luc and CD63-GFP were cultured in a standard growth media comprised of Dulbecco’s Modified Eagles Medium (DMEM) supplemented with 10% EV depleted fetal bovine serum (FBS) and 1% Penicillin Streptomycin. Cells were maintained at an atmosphere of 37 °C and a humidity of 5% CO2 and regularly subcultured once confluency of 70%-80% was reached. Upon reaching 80% confluency, cells were split with fresh media and allowed to undergo two rounds of passaging after cracking vials.

Animals

All animal husbandry and procedures involving mice in this study were conducted under the Center for Discovery and Innovation IACUC approved protocol (#288.00) in an Association for Assessment and Accreditation of Laboratory Animal Care International (AAALAC) accredited research animal facility in accordance with all NIH guidelines for the use and care of experimental animals.

Tumor inoculations for lung metastasis

On the day of tumor inoculations, TdTomato-Luc+/CD63-GFP + MDA-MB-231 subline 3475 cells were trypsinized and counted prior to being resuspended in warm 1x sterile PBS at a concentration of 1 × 106 cells per 200 μL. Immediately after cell preparations, a heating pad was placed under one side of the cage to “pre-warm” and dilate veins of athymic BALB/C mice, animals were restrained, and the lateral tail vein was located. The needle was inserted parallel into the vein and cells slowly injected. Any bleeding at the injection site was stopped by applying gentle compression and animals were returned to their cage and monitored.

In vivo bioluminescence imaging

Animals were anesthetized by isoflurane inhalation prior to receiving an intraperitoneal (I.P.) injection of D-luciferin (150 mg/kg). 15 min after D-luciferin administration, animals were placed onto the warming pad in the imaging box of an IVIS instrument, oriented so that tumors located in the lungs were well within the imaging area. Anterior images were acquired using the auto-exposure feature. Animals were imaged once a week for the duration of the study to: (i) determine the site of cancer cell growth; and (ii) monitor tumor burden.

Animal condensate collection using the RC3 dual mouse chamber

Animal condensate collection was achieved by placing two mice together into a sterile glass RC3 respirometer chamber (Sable Systems International) attached to a SS4 flow pump/meter set to a rate of ~2.0 mL/min. The flow pump/meter sets the rate of inlet air into the chamber, with the ~2.0 mL/min setting being the recommended flow rate needed to allow for enough air flow into the chamber to prevent mice from suffocating during the collection period. The RC3 respiratory chamber is large enough to easily allow two mice to be placed in the chamber and does not lead to significant restraint (length = 10 and diameter = 3), as mice still have freedom to move around with normal postural movement (i.e., walk and turn around freely). Mice were kept in the chamber for one h to allow for adequate volumes of condensate to be collected. EBC collection was performed every week for the duration of this 16-week study.

Exhaled breath condensate collection using a single mouse nose-mouth device

To collect exhaled breath condensate (EBC) from single mice without the risk of contamination from urine, skin and feces, we modified the design and setup of the single breath collection device described by Liu et al. in 2019[96]. For this method of EBC collection, single mice were placed into the modified mouse restrainer designed to expose only the nose-mouth of mice, enabling uncontaminated collection of EBC. The design of our single-mouse EBC collection device involves placing the mice into a restrainer that does not allow the mice to turn around so that maximum EBC volumes can be obtained. Since the use of full body restraint of animals can lead to enhanced stress, we designed the restraint in such a way that the head and torso of the animals were held within a dark chamber, allowing for animals to be within a dark enclosed space to reduce anxiety throughout the collection time-period (IACUC approved). Our single-mouse EBC collection device utilizes the same flow pump/meter described above for the collection of EBC from a dual mouse chamber, and the rate of inlet air into the chamber will be set to ~2.0 mL/min. Additionally, in order to ensure one-way air flow, a second flow meter will be attached to the other end of our collection (condensation) chamber and will be set to a flow rate of ~0.2 mL/min. Since our single collection device was smaller in size to ensure the collection of EBC only from the nose-mouse of animals, these collections provided smaller volumes of EBC and were performed for 2 h three times a week. The IACUC committee identified the duration and frequency of our collection acceptable to prevent animal stress throughout the duration of this study (24 weeks).

Lung tissue collection and H&E staining

At the end of the study period, mice were sacrificed and lungs were perfused and inflated for tumor histological examination by inserting a 3 mL syringe with a 22 g needle attached into the trachea and slowly inflating the lungs with 10% formalin at a rate of approximately 200 μL/sec until the lungs have fully inflated. Following inflation, the trachea was severed, and the lungs removed from the respiratory cavity and placed into a tube containing 10% buffered formalin and were fixed for 24 h. Following fixation, lungs were processed by histological sectioning and H&E staining at the Histology & Comparative Pathology core facility at the Albert Einstein College of Medicine, Bronx, NY.

Spectradyne microfluidic resistive pulse sensing

Particle size distribution of exhaled EVs isolated from mouse EBC was performed using microfluidic resistive pulse sensing (MRPS) measurements on a nCS1 instrument (Spectradyne LLC, Signal Hill, CA). Initially, the microfluidic system was primed using a solution of 0.2 µm filtered PBS containing 1% Tween 20 (v/v). For each purified exhaled EV sample, 2 μL was loaded onto a C-400 cartridge (i.e., analysis of particles between 65 and 400 nm), and the instrument pressure and voltage parameters were automatically determined using the instrument software. Acquisition of data from > 6,000 particle detection events was collected for each sample, and all data were combined into a single stats file and using the nCS1 Data Viewer software, peak filters and background subtraction were applied, according to the manufacturer’s recommendations. Peak filters set were (i) transit time < 60 μs; (ii) diameter > 65 nm, and signal-to-noise ratio (S/N) > 10. Additionally, combined stats files were analyzed for size distribution and particle concentration and peak-filtered CSD graphs were generated.

EV-CATCHER isolation of the extracellular vesicles

The isolation of LM-3475 EVs in vitro and exhaled EVs from EBC collected in vivo was performed using the EV-CATCHER isolation protocol described by Mitchell et al. in 2021, customized with either human-specific CD63 or mouse-specific anti-CD63 capture antibodies[97]. Briefly, equimolar amounts of 5’-Azide modified and 3’-Biotin modified oligonucleotides (Integrated DNA Technologies) were annealed in 1x RNA annealing buffer, prior to separation on a 15% non-denaturing polyacrylamide (PAGE) gel. The double-stranded (ds) DNA product was visualized using SYBR® Gold™ (ThermoFisher, cat#S11494), excised, crushed, resuspended in 400 mM NaCl and placed on a thermomixer set to 4 °C and 1,100 RPM overnight. The solution was filtered, and the dsDNA linker was purified using the QIAEX® II gel extraction kit (Qiagen, cat#20021) according to the manufacturer’s instructions. Capture antibodies (1 mg/mL) were activated using 5 µL of freshly prepared 4 mM DBCO-NHS ester (Lumiprobe, cat#94720) and incubated for 30 min at room temperature (RT) in the dark; reactions were stopped by adding 2.5 µL of 1M Tris-Cl (pH 8.0) at RT for 5 min in the dark. DBCO-activated antibodies were desalted using Zeba desalting columns (ThermoFisher, cat#89882), and quantified on a Nanodrop 2000 instrument prior to the preparation of antibody-dsDNA (Ab-dsDNA) stock solutions. Ab-dsDNA conjugates were then bound to streptavidin-coated 96-well plates (Pierce, cat#15120) and wells were washed three times with cold 1x PBS solution, prior to the addition of RNase-A (12.5 μg/mL) treated samples (100 μL). Plates were sealed using microAMP optical adhesive film (Applied Biosystems, cat#4311971) and placed on a shaker at 300 RPM at 4 °C, O/N. Samples were carefully removed, and wells were washed 3 times with cold 1 × PBS, and 100 μL of freshly prepared uracil glycosylase (UNG) enzyme (ThermoFisher, cat#EN0362) in 1 × PBS [1 × UNG buffer 200 mM Tris-Cl (pH 8.0), 10 mM EDTA, and 100 mM NaCl], with 1 unit of enzyme, was added to each well. Plates were incubated at 37 °C for 2 h on a shaker at 300 RPM for UNG digestion of the dsDNA linker, and isolated EVs were collected for downstream analyses. For evaluation of the anti-human anti-CD63 EV-CATCHER assay, we conducted in vitro EV uptake experiments using EVs produced by LM-3475 cells transduced with a pCT-CD63-GFP lentivirus. A total of 180 mL of media was ultracentrifuged and the pelleted EVs were quantified using a Spectradyne nCS1 instrument. Half of the isolated EVs were subjected to the anti-human anti-CD63 EV-CATCHER assay and both EV-CATCHER and ultracentrifugation isolated EVs were used for in vitro uptake analyses, where non-transduced LM-3475 cells were treated with 1 × 1010 isolated EVs and confocal microscopy was performed to evaluate EV uptake, by measure of GFP fluorescence. All other EV-CATCHER purifications were conducted using mouse EBC collected in vivo using our EBC collection systems.

Transmission electron microscopy

Transmission electron microscopy (TEM) of exhaled EVs purified by ultracentrifugation and the EV-CATCHER assay, obtained from 3 mL of mouse EBC (i.e., collected from six mice over a period of three weeks), was performed at the Analytical Imaging Facility at the Albert Einstein College of Medicine, Bronx, NY.

ONi super-resolution nanoimaging

Exhaled EVs purified from mouse EBC by ultracentrifugation of 1 ml of EBC collected with our v2.0 system from lung tumor-bearing female mice (weeks 19-22) and from 3 mL of EBC from control female mice (weeks 19-22), were processed for nanoimaging on the highly sensitive ONi super-resolution Nanoimager using the ONi human EV Profiler kit v2.0 customized for the capture and assessment of EVs immobilized using their proprietary S4 capture molecule which binds phosphatidylserine present on all EVs. Mouse EVs ultracentrifuged from control female mice were only tested as a negative control, as ONi does not manufacture a mouse EV profiler kit. Human EV capture and staining was performed according to manufacturer protocol, and image acquisition on the ONi super-resolution Nanoimager was performed in the NimOS Light program with a 640 dichroic split using the following parameters: 640 nm laser set to 20%-30% laser power, the 560 nm laser at 35% laser power, and the 473/488 nm laser set to 70% laser power. Technical support from ONi provided information that during image acquisition, the fluorescent wavelength of TdTomato could not be excited and captured by either of the three pre-calibrated lasers and that the analysis of potential GFP signal was not detected in any of our raw data. The number of runs (frames) for all laser lines was set to 1,000 and all image analyses were performed using CODI software.

Small-RNA extractions

Small-RNA extractions from exhaled EVs were performed using the miRNeasy Serum/Plasma kit (Qiagen, Cat#217184) according to the manufacturer’s instructions, with some modifications to improve total RNA yield. Briefly, QIAzol was added to 100 µL of purified exh-EVs, vortexed and incubated at RT for 3 min, after which chloroform was added to each sample. Samples were vortexed again and incubated at RT for 3 min. Samples were then centrifuged at 12,000 × g, at 4 °C for 15 min, and the upper aqueous phase was carefully removed and transferred into new siliconized 1.5 mL Eppendorf tubes, to which 100% ethanol and 2 µL of miRNA-Seq 19 nt/24 nt (1.5 ng + 1.5 ng) size marker required for NGS library preparations was added to each sample. Samples were incubated on ice for 40 min prior to undergoing column purification, where each sample was passed twice through RNeasy MinElute columns, followed by a working solution of RPE wash buffer, and finally ice-cold 80% ethanol. Columns were spun to remove residual ethanol, and total RNA was eluted with 50 µL of RNase-free water and samples were speed-vacuumed to 9.5 µL prior to small-RNA sequencing.

Small-RNA cDNA library preparations

Small-RNA sequencing from EVs purified from mouse exhaled breath condensate (EBC) was performed using the cDNA library preparation protocol described by Loudig et al.[98], with modifications for low input RNA from purified small EVs[97]. In brief, small-RNA cDNA libraries were prepared using total RNA recovered from condensates, whole EBC, or exhaled EVs purified with EV-CATCHER from EBC. 18 RNA samples underwent individual ligations using truncated K227Q T4 RNA Ligase 2 (New England Biolabs, cat#M0351L) for barcoding with 3’ adapters. The next day, ligations were heat inactivated at 90 °C for 1 min, combined, precipitated on ice, and centrifuged for 1 h at 14,000 RPM, at 4 °C. The pellet was dried, resuspended, and ligated miRNAs were size-selected on a 15% Urea-PAGE gel, excised, and incubated in 400 mM NaCl O/N at 4 °C, at 1,100 RPM on a thermomixer. The next day, the solution was filtered, precipitated, and a RNA pellet was obtained by centrifugation at 14,000 RPM for 1 h at 4 °C. The 5’ adapter was added to the resuspended pellet using T4 RNA Ligase 1 (New England Biolabs, cat#M0204L) for 1 h at 37 °C. The ligated product was separated on a 12% Urea-PAGE gel, size-selected, and excised; the gel fragment was crushed, resuspended in 300 mM NaCl solution with 1 mL 100 M 3’ PCR primer, and incubated O/N on a thermomixer at 1,100 RPM at 4 °C. The next day, the solution was filtered, precipitated with 100% ethanol, incubated on ice for 1 h, and pelleted by centrifugation for 1 h at 4 °C. The RNA pellet was resuspended, and underwent reverse transcription using SuperScript® III Reverse Transcriptase (ThermoFisher, cat#18080-093) at 50 °C for 30 min. The reaction was deactivated at 95 °C for 1 min, and a pilot PCR reaction was set up to identify the ideal amplification cycle. Large-scale PCR reactions were set up, combined, precipitated, digested with PmeI for removal of size markers, and separated on a 2.5% gel. The 100 nucleotide PCR library product was excised, purified with QIAquick Gel Extraction Kit (Qiagen, cat#28704), and quantified. cDNA libraries were then sequenced (single-read 50 cycles) on a HiSeq2500 Sequencing System, after which FASTQ files containing raw sequencing data were processed for adapter trimming and small-RNA alignment to the hg-19 genome.

miRNA data analysis

Raw FASTQ data files obtained on an Illumina HiSeq2500 sequencer were processed using the RNAworld server from the Tuschl Laboratory at the Rockefeller University, including adapter trimming and read alignments and annotation. MiRNA counts were exported to spreadsheets for data analysis. Statistical analyses of miRNA counts were performed using dedicated Bioconductor packages in the R platform, as detailed below. Heat maps were generated from transformed counts using the “NMF” package (aheatmap function). Differential expression was assessed using “DESeq2” and “edgeR”. Differential expression models included a batch variable (library) to reduce batch biases. To maximize the discrimination ability of miRNA, we computed a score for each sample (“miRNA score”[99]), assembled by summing the standardized levels (z-values) of all significantly upregulated miRNAs, and the negative of the z-values of all significantly downregulated miRNAs.

Proteomic data analysis

We conducted proteomic analyses on EBC samples collected with our v1.0 system and separately combined from the EBC of 6 control mice (i.e., 3 males and 3 females) and the EBC of 6 lung tumor-bearing mice (i.e., 3 males and 3 females). We estimated the total protein content of each of these two EBC samples (i.e., control and lung tumor-bearing samples) to be 53 ng and 76 ng, respectively. We also conducted proteomic analyses on EBC samples collected with our v2.0 system and separately combined EBC from 3 female control mice and from 3 female lung tumor-bearing mice and estimated the total protein content to be 29 ng and 38 ng, respectively. Proteins present in mouse EBC were analyzed by a workflow integrating suspension trapping (S-Trap)-based sample processing and data-independent acquisition mass spectrometry (DIA-MS) was recently described for the analysis of low input EV proteins[100]. In brief, proteins were extracted with 5% SDS, reduced with DTT, alkylated with iodoacetamide, and then digested on a S-Trap column (ProtiFi, LLC) with sequencing-grade trypsin/Lys-C (Promega). The resulting peptides were analyzed with a nanoAcquity UPLC system (Waters) coupling with an Orbitrap Fusion Lumos mass spectrometer (Thermo Fisher) in DIA mode, with parameters similar to those described previously[100]. The DIA data files were processed by Spectronaut (Biognosys) with default settings, and the peptides identified were aligned against mouse and human protein databases. For proteins identified from EBC collected with our v1.0 system, we identified a total of 448 proteins and a total of 333 proteins from EBC collected with our v2.0 system. Differential expression analyses [i.e., Ratio of lung tumor-bearing protein reads/control protein reads from condensates (v1.0 system) and EBC (v2.0 system)] of proteins commonly detected between lung tumor-bearing and control mouse biofluids [i.e., condensates (v1.0 system) and EBC (v2.0 system)] are displayed as heat maps.

RESULTS

Orthotopic tumor-bearing mouse model of secondary lung cancer

The goal of our proof-of-principle study was to determine whether secondary lung cancer can be detected non-invasively at an early stage through the analysis of exhaled breath condensates. Thus, we selected an aggressive human metastatic breast cancer cell line (MDA-MB-231 subline 3475), which was developed by the group of Dr. Massagué, that, when delivered via tail vein injection, migrates and colonizes the lungs, rapidly forming expanding lung tumor foci within 15 weeks[101]. In previous studies, we demonstrated that these cells preferentially colonized the lungs of athymic BALB/C mice and led to a heavy tumor burden within 16 weeks[102,103]. Prior to conducting our in vivo analyses, we stably transduced these cells with the pUltraChili-Luc construct (TdTomato-Luc; 9947bp) [Supplementary Figure 1], as its luciferase production enables reduction of D-luciferin that is injected intraperitoneally (150 mg/kg) in anesthetized animals for release of bioluminescence and in vivo imaging of tumor growth. We also transduced these cells with the pCT-CD63-GFP Cyto-Tracer lentivirus (i.e., SBI, cat# CYTO120-VA-1, detailed in Supplementary Figure 1) to evaluate the purification and uptake of their extracellular vesicles in vitro [Supplementary Figure 2]. We used fluorescent activated cell sorting (FACS) to select for double-positive cells expressing both TdTomato-Luc [i.e., Supplementary Figure 1A] and CD63-GFP [i.e., Supplementary Figure 1B]. Single-cell expansion of double-positive LM-3475 clonal cells (i.e., high co-expression levels) was confirmed by confocal imaging in Figure 1A, using DAPI nuclei staining (blue; first panel), TdTomato-Luc (red protein, second panel) and CD63-GFP (green fluorescent protein; third panel). As cells were asynchronous and at different stages of mitosis, we observed different intensities of the GFP signal, indicating different production levels of CD63-GFP labeled EVs (Figure 1A, comparing GFP signal of central dividing cell with surrounding growing cells in third panel). Our double-positive LM-3475 clone was expanded in vitro and delivered via tail vein injection (i.e., 1 × 106 LM-3475 cells) into male and female athymic BALB/C mice for our tumor-bearing animal group [Supplementary Figure 1C]. We conducted in vivo imaging weekly to monitor tumor localization and evaluate tumor burden in individual mice. We detected bioluminescent signal in the thoracic area of mice within 6 weeks after tail vein injection of double-positive LM-3475 cells [Figure 1B], which was consistent in all animals by 12 weeks [Figure 1B]. Our animals were sacrificed at 16 weeks, and we observed large macroscopic tumor lesions in the lungs of tumor-bearing animals [Figure 1C]. Our pathological evaluations revealed the presence of both microscopic tumor foci and large tumors within lung tissues [Figure 1D]. We did not observe significant differences in the growth or number of tumors between males and females.

Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles

Figure 1. Establishment of the mouse model of human secondary lung cancer. (A) MDA-MB-231 subline 3475 cell line stably transduced with lentiviral constructs for expression of TdTomato-luciferase (pUltraChili-Luc) and pCT-CD63-GFP. Confocal imaging of a single clone co-expressing both TdTomato and GFP, sorted by FACS [See Supplementary Figure 1], with DAPI staining to locate cellular nuclei (Blue color, left panel) and Td-tomato red protein expression (Red colored cells, second panel from the left) and the CD63-GFP protein on extracellular vesicles (EVs, Green dots, third panel from the left), with a Merged image all staining and fluorescent imaging on the right panel. CD63-GFP detection shows that cells at different mitotic stages produced different amounts of EVs as observable by the differential detection of GFP protein. The central dividing cell displays the highest amount of observable EVs; (B) Bioluminescent in vivo imaging of tumor-bearing mice at weeks 0, 6, and 12 after inoculation of TdTomato-Luc+/CD63-GFP+ MDA-MB-231 subline 3475 cells. Bioluminescence intensity is indicated by means of radiant efficiency (photons/sec/cm2/sr) scale bars, with red being the most intense (See scale bar); (C) Representative formalin-fixed whole lung tissue images collected from two healthy mice (control; left) and two TdTomato-Luc+/CD63-GFP+ MDA-MB-231 subline 3475 inoculated lung tumor-bearing mice (case; right); (D) Representative images of Hematoxylin and Eosin (H&E) stained 5 mm tissue sections of lungs harvested from one control (left panels; 0 × and 20 × magnifications) and one lung tumor-bearing animal (right panels; 0 × and 20 × magnifications). The image right panel from one lung tumor-bearing animal shows extensive infiltration of metastatic carcinoma legions with a few rare immature lymphocytes seen interspersed.

Evaluation of a whole mouse condensate collection system (Version 1.0)

For these experiments, we sought to determine whether whole mouse condensates could be collected from unrestrained lung tumor-bearing and control athymic BALB/C mice. Utilizing the Sable Systems International (SSI) classic instrumentation line, we combined devices to enable collection of condensates in this air-tight system [Figure 2]. Using the SS4 pump (Figure 2A; flow rate of 2 mL per min), compressed breathing-grade air was circulated through a one-way Balston air flow filter (Figure 2B, to prevent air backflow) and through 1/4 inch tubes into the successive chambers [Figure 2C and E]. The first was the animal glass chamber (Figure 2C; accommodates up to two mice) that was sealed on both ends by caps with double gaskets to prevent air leakage [Figure 2D]. This chamber was fitted with a removable metal grate to allow mice to move freely and to allow urine and feces to drop in the lower section of the glass chamber. As the air was continually pushed through the mouse glass chamber, it was then directed towards a second small glass chamber (Figure 2E; the condenser), which was set on ice to enable condensation of animal aerosolized biofluids (condensates). This glass condenser was also sealed on both ends with tight-fitting endcaps equipped with double gaskets that prevented air leakage. For our experiments, we collected condensates from animal pairs of the same sex weekly for 16 weeks. Our weekly collections revealed that we could condense an average volume of ~62.5 µL of biofluid in each condenser within one h [i.e., average collected over 96 collections (3 animal pairs × 1 collection per week × 16 weeks × 2 groups)]. For our experiments, we collected three distinct condensates from dedicated animal pairs, separately from males (n = 6; 3 pairs) and females (n = 6; 3 pairs), both from our control (6 males and 6 females) and lung tumor-bearing (6 males and 6 females) animal groups.

Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles

Figure 2. Whole mouse exhaled breath condensate (EBC) collection system version 1.0. For this system, EBC is collected from two unrestrained mice roaming in a sealed glass chamber, which contains a removable metal grate that allows animals to move freely with normal postural movement. Airflow throughout the system is maintained and directed towards a condenser. The components of this mouse EBC collection system include: (A) an air pump that controls airflow (2.0 mL/min) of compressed breathing-grade air that is transported through 1/4 inch plastic tubes; (B) a one-way Balston 0.01 mic 93% airflow filter that maintains air sterility; (C) a glass mouse chamber (containing two mice); that is (D) securely sealed on both ends by caps with gaskets; connected to (E) a glass condenser sealed on both ends by caps, which is placed on ice to allow for the collection of EBC. It is estimated that ~62.5 µL of EBC can be captured from two mice within one h of collection.

miRNA expression analyses of whole mouse condensates

As we recently demonstrated that miRNAs are detectable in human EBC and that they may have diagnostic value for the detection of lung cancer[43], we investigated whether microRNA expression analyses of our condensates could likewise distinguish mice with secondary lung tumors from control mice. We separately combined condensates from male pairs and from female pairs for each group and at each time point to enable RNA extractions from at least 100 µL biofluid. Then, using our optimized assays[97,98], we conducted small-RNA next-generation sequencing (NGS) analyses of mouse condensates collected at weeks 0, 5, 9 and 13 from control females [Figure 3A, blue circles (n = 6)], control males [Figure 3A, blue triangle (n = 6)], and lung tumor-bearing females [Figure 3A, red circle (n = 6)], and lung tumor-bearing males [Figure 3A, red triangle (n = 6)]. Control male and female mice had received a mock injection of 1 × PBS at the same time as tumor-bearing male and female mice had received 1 × 106 LM-3475 cells, which were delivered via tail vein injection at week 0, to eliminate experimental biases due to biofluid injections. Principle Component Analysis (PCA) plots revealed that the miRNA profiles captured from control male and female mice were consistent across the 16 weeks of collection [Figure 3B, control (blue)], but revealed differences between week 0 and weeks 5, 9, and 13 for lung tumor-bearing male and female mice [Figure 3B, tumor (red)]. Furthermore, we observed that the miRNA profiles of condensates collected at weeks 5, 9, and 13 from lung tumor-bearing mice clustered together, were consistent between males and females, but were highly different from those of male and female control mice [Figure 3C]. We noted that the miRNA profiles of condensates collected at week 0, following tail-vein injection of LM-3475 cells for lung tumor-bearing male and female mice, clustered together with those of control male and female mice [Figure 3C]. Overall, our miRNA profiles identified a set of miRNAs common between the control and tumor groups (Figure 3C, purple rectangle), and a set of tumor-associated miRNAs mostly detectable in the tumor group at weeks 5, 9 and 13, in both males and female mice (Figure 3C, red rectangle). Although we identified miRNA expression differences between the condensates of control and tumor groups, we could not fully determine whether all these miRNAs were of human (tumor cell) or mouse (mouse tissues) origin due to strong sequence homology between these two species.

Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles

Figure 3. MicroRNA analysis of EBC collected from unrestrained animals. (A) Timeline of the weekly EBC collections from animal pairs, separated by sex (circles for females, triangles for males), between healthy control mice (blue) and lung tumor-bearing mice (red), for a period of 16 weeks. Discovery analyses were performed using total small-RNA extracted from EBC collected at weeks 0, 5, 9, and 13 using Next-Generation Sequencing (NGS). Validation analyses were conducted using total small-RNA extracted from EBC at weeks 1, 8, and 15 using quantitative reverse transcription PCR (RT-qPCR). Proteomic analyses were conducted on EBC collected and pooled for weeks 12, 14, and 16 from control and tumor-bearing mice groups; (B) PCA plots for miRNA expression of healthy control mice measured at weeks 0, 5, 9, and 13 for both females and males (top), and lung tumor-bearing mice at the same time points for both females and males (bottom); (C) Heatmap classification of the top 233 miRNAs detected by NGS using small RNAs extracted from EBC of healthy control (blue) and lung tumor-bearing (red) mice at weeks 0 (yellow), 5 (green), 9 (pink), and 13 (purple) for both females (grey) and males (black). The purple box highlights miRNAs commonly identified between condensates from control and lung tumor-bearing animals. The red box highlights miRNAs predominantly identified in condensates obtained from lung tumor-bearing animals. Two miRNAs, namely miR-374a and miR-584, which are bolded in orange text, are identified to be predominantly upregulated in condensates of lung tumor-bearing animals and are also identified to be upregulated in EBC obtained from lung tumor-bearing animals (system v2.0) displayed in Figure 7C and D. Taqman© qPCR analyses of hsa-miR-222 and has-miR-210 using total small-RNA purified from EBC collected at weeks 1 (blue), 8 (light purple), and 15 (dark purple), separately for females and males, with data calculated using the 2ΔΔCt formula between healthy mice (i.e., using week 1 Ct values as the reference), and lung tumor-bearing mice, both normalized to exogenous ath-miR-159a (100 pg) as an internal “housekeeping” control that was spiked in EBC before RNA extractions and qPCR analyses.

As we sought to determine if we could conduct early and non-invasive detection of secondary lung tumors by analysis of miRNAs contained in condensate, we selected miR-222 and miR-210, which displayed high read counts by NGS, and had been reported in the literature for their increased expression in the circulation of women diagnosed with metastatic breast cancer[104,105], to conduct our qPCR analyses [Figure 3D]. Our qPCR data confirmed their upregulated expression in condensates of lung tumor-bearing mice, but also revealed that their expression increased between weeks 1, 5, and 8 for both lung tumor-bearing males and females [Figure 3D]. We also noted that comparatively, the increase in expression of both miR-222 and miR-210 was higher in the combined condensates of lung tumor-bearing female mice than in those of male mice. Particularly, we observed that increased expression of both miR-222 and miR-210 was detectable in condensates of lung tumor-bearing female mice only one week after tail-vein injection of LM-3475 cells, but not in male mice. Our analyses demonstrated that miRNAs contained in condensates collected with our v1.0 system could discriminate control from lung tumor-bearing mice. Our data also suggested that metastatic human female breast cancer cells were detectable quicker in female than in male tumor-bearing mice.

Proteomic analyses of whole condensates

Although our experiments indicated that condensates collected with our v1.0 system contained miRNAs that could discriminate control and lung tumor-bearing mice, we could not confirm that the condensed biofluids were solely obtained from exhaled breath. Indeed, upon the transfer of condensates to Eppendorf tubes, we could generally detect a smell of urine emanating from our condensates. Therefore, we sought to investigate the protein content of this biofluid to estimate tissue contribution, and used the S-trap-based sample processing coupled with DIA-MS proteomics approach, a workflow that we previously developed for the robust and ultra-sensitive proteomic analysis of low input proteins (as low as 5 ng input;[100]). We conducted these proteomic analyses on whole mouse condensates combined separately from 6 control (i.e., 3 male and 3 female mice with 53 ng of total protein input) and 6 lung tumor-bearing mice (i.e., 3 male and 3 female mice with 76 ng of total protein input), collected at weeks 12, 14, and 16 [Figure 4]. Our analyses identified a total of 448 proteins between condensates of control and lung tumor-bearing mice. We determined that 232 proteins were common to both control and lung tumor-bearing mouse condensates but that 216 were unique human proteins, which were only detected in condensates of lung tumor-bearing mice. When evaluating the 55 most differentially expressed proteins, common to both control and lung tumor-bearing mouse condensates (Supplementary Figure 3; aligning to both human and mouse protein sequences), we identified several upregulated proteins in the condensates of lung tumor-bearing mice, of which some have been correlated with pro-metastatic properties in previous studies (Supplementary Figure 3; Plectin, Gelsolin, Vimentin, β1 integrin, Integrin a6, α-enolase, S100A4)[100,106-107]. Due to the high sequence homology between human and mouse for these 55 proteins, mouse tissue or human tumor contribution could not be confirmed. However, when we conducted putative tissue origin analysis of the 232 proteins (i.e., based on prominent tissue expression determined in ProteinAtlas) common to both control and lung tumor-bearing mouse condensates, we determined that a large proportion could be categorized to other tissue origins than the lung or respiratory system (Figure 4, skin, urine, upper digestive tract, colon, testes, and breast).

Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles

Figure 4. Proteomic analysis of EBC from healthy controls and lung tumor-bearing mice. Pie chart distribution of all 286 identified proteins in pooled EBC samples of control (n = 6) and lung tumor-bearing (n = 6) mice, stratified based on the preferential organ/tissue origin of each individual protein as informed by ProteinAtlas, and distributed as either from lung, skin, urine, breast, testis, colon, or undetermined tissue origins (i.e., Other).

Evaluation of a nose/mouth targeted exhaled breath condensate collection system (Version 2.0)

Since our low output proteomic analyses suggested that whole animal collection of condensates introduced protein contaminants from tissue sources other than the lung, to improve our miRNA expression analyses, we sought to focus our collection on exhaled breath condensates. Thus, we improved the design of our collection system by including a mouse restraining device (i.e., as described by Liu et al.[96]) and by including an exhaled breath collection chamber to allow targeted capture of exhaled breath condensate (EBC) directly from the nose/mouth of individual mice [Figure 5]. Similarly to that of our v1.0 collection system, this system included an air pump (Figure 5A; set at 2 mL per minute) supplying compressed breathing-grade air, a one-way airflow Balston filter [Figure 5B] to enable unidirectional air flow, an exhaled breath collection chamber (Figure 5C; see blue arrows for airflow) that was sealed by a gasket at its connection at the end of the mouse restrainer [Figure 5D], and a sealed glass condenser [Figure 5E]. In order to enhance airflow, we added an air pump to gently pull air from the end of the condenser (Figure 5F; set at 0.2 mL per min). Importantly, we determined that within a 2-h collection window (i.e., the maximum allowed time by the internal IACUC committee), we could collect an average of ~29 µL of EBC from individual mice. Due to the collection of a lower EBC volume with our v2.0 collection system than with our v1.0 system (i.e., 63 µL per h), for experimental and feasibility reasons, we chose to analyze combined EBC samples (i.e., 3 control mice or 3 lung tumor-bearing mice) to reach a total working volume of 100 µL. Since we did not observe differences in the identity of the miRNAs differentially expressed in condensates collected from male and female lung tumor-bearing mice with our v1.0 system, but we observed increased detectability of miR-222 and miR-210 at earlier stages of disease (i.e., at week 1) in female mice compared to male mice, we chose to conduct our proof-of-principle miRNA NGS and qPCR analyses of EBC collected with our v2.0 EBC collection system from female mice only. This was further supported by the fact that the incidence of male breast cancer and its metastasis to the lung is extremely rare[108], and that our cells were of female breast cancer origin.

Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles

Figure 5. Nose and mouth EBC collection system v2.0 for restrained individual animals. The system designed and described here includes additional devices that enable air flow and direct collection of EBC from the nose and mouth of restrained mice. The system is composed of: (A) an air pump controlling airflow (2.0 mL/min) from an air tank transported by 1/4 inch tubes; (B) an airflow valve to maintain air directionality and sterility; (C) an exhaled chamber that is tightly connected with gaskets; to the (D) mouse immobilization chamber where the animal is restrained and through 1/4 inch tubes; towards (E) a glass condenser sealed on both ends by caps and sitting on ice for the accumulation of EBC droplets; which is connected to (E). a second air pump set up in vacuum mode to enhance air circulation through the entire system (i.e., set at 0.2 mL/min). This system allows for individual collection of ~29 µL EBC from restrained mice within 2 h.

Detection of human tumor extracellular vesicles in mouse EBC

As determined in previous studies, EBC collected with different types of condensing devices from humans has been found to contain EVs[48-50]. Thus, for this proof-of-principle study, we sought to determine whether EBC collected from the nose/mouth of restrained mice also contained EVs. Thus, we conducted nanoparticle analyses of whole EBC collected with the v2.0 EBC collection system from both control and lung tumor-bearing mice using our Spectradyne Nanoparticle Analyzer nCS1 instrument [Figure 6A]. Our analyses of EBC collected and pooled from three mice at weeks 2, 6, and 11 revealed that nanoparticles of 65-150 nm in diameter were detectable from both control (n > 57 nanoparticles, Figure 6A top graph) and lung tumor-bearing mice (n > 1,663 nanoparticles, Figure 6A bottom graph), but that they were present at much greater concentrations in the EBC of lung tumor-bearing female mice than control female mice. Additionally, we observed that the number of nanoparticles detectable in EBC of lung tumor-bearing mice between weeks 2 and 11 nearly doubled (Figure 6A; from 1,663 at week 2 to 2,651 particles at week 11). Next, we performed Transmission Electron Microscopy (TEM) on EVs ultracentrifuged from 1 ml of EBC collected and combined from 6 lung tumor-bearing female mice between weeks 19 and 22 using our v2.0 collection system (Figure 6B; bottom panels). Since our Spectradyne analyses showed that EVs from control mice were in much lower concentrations, we collected and combined 3 ml EBC obtained from 6 control female mice over a period of six weeks and then conducted ultracentrifugation and TEM analyses [Figure 6B]. EVs detectable from EBC of control and lung tumor-bearing female mice were ~80-100 nm in diameter [Figure 6]. Since our analyses indicated that EBC collected from lung tumor-bearing mice contained a higher number of nanoparticles, we sought to determine whether this increase was due to an output of human tumor EVs. Thus, we used the ONi human EV profiler kit to conduct super-resolution nanoimaging [Figure 6C]. With this kit, phosphatidylserine present in the membrane of EVs is bound onto the ONi platform with a proprietary S4 capture molecule, and they are then evaluated for presence of human CD9, CD63, and CD81 tetraspanin proteins by laser detection of their three individually fluorescently labeled anti-human antibodies [Figure 6C]. We note that the scanning wavelength of each of the three lasers used to detect these three fluorescent antibodies did not coincide with the fluorescent signal of TdTomato and that no signal was detected for GFP in any raw data files acquired from the imaging of exhaled EVs. Since a mouse EV profiler kit was not manufactured by ONi, our EV validation analyses were focused only on human EVs. Our analyses revealed that we could not detect human CD9, CD63, and CD81 from mouse EVs pelleted by ultracentrifugation from 3 mL of control mouse EBC and tested on the ONi platform (Figure 6C; upper panels). We also note that this volume was three-fold the volume of EBC collected and ultracentrifuged from lung tumor-bearing mice (i.e., 1 mL) and thus three-fold the input of mouse EVs present in EBC collected from lung tumor-bearing mice. Our analyses showed that we could individually detect human CD9, CD63, and CD81 proteins on the surface of EVs immobilized on the ONi platform, which were purified by ultracentrifugation of 1 mL EBC from lung tumor-bearing mice (Figure 6C, lower panels). We displayed scans of the ONi grids for all detectable EVs in Supplementary Figure 4. Our results suggest that the ONi human EV profiler kit could not capture or identify human CD9, CD63, or CD81 tetraspanins on EVs ultracentrifuged from the EBC of control mice (Figure 6C; top panels), but identified all three proteins on EVs ultracentrifuged from the EBC of lung tumor-bearing mice.

Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles

Figure 6. Purification and analysis of exhaled extracellular vesicles from mouse EBC. EBC collected directly from the nose and mouth of individual animals was evaluated for the presence of exhaled EVS. (A) EBC from healthy control (n = 3) and lung tumor-bearing (n = 3) mice collected at weeks 2, 6, and 11 was evaluated using the Spectradyne nCS1 nanoparticle analyzer, using C400 cartridges for the detection of nanoparticles between 65 and 400 nm; (B) EBC samples from 6 control (left; 3 mL) and 3 lung tumor-bearing (right; 1 mL) mice, collected over 4 weeks, were subjected to ultracentrifugation and the pellets analyzed by imaging using transmission electron microscopy (TEM); (C) EV pellets from healthy control (top panels) and from lung tumor-bearing mice were analyzed using Super-Resolution Microscopy (ONi instrument) using anti-human anti-CD63, anti-CD9, and anti-CD81 anti-tetraspanin antibodies to evaluate the size and identity exhaled EVs contained in the ultracentrifuged EBC pellets of control (top panels) and lung tumor-bearing mice (bottom panels).

miRNA analyses of EBC and exhaled EVs collected directly from nose/mouth

Next, we sought to evaluate the utility of our EV-CATCHER assay customized for species-specific purification of exhaled EVs from mouse EBC[97]. Thus, we selected a human-specific and a mouse-specific anti-CD63 antibody to purify and conduct comparative miRNA expression analyses of human and mouse EVs contained in the EBC of control and lung tumor-bearing mice. We chose an anti-human anti-CD63 customized EV-CATCHER assay for the purification of human EVs from mouse EBC, as opposed to an anti-GFP antibody (i.e., CD63-GFP labeled EVs are produced by LM-3475 cells in Figure 1A), because we had demonstrated its high affinity for human EVs in a previous study[97]. Due to the limited availability of exhaled EVs, we initially tested the ability of our anti-human anti-CD63 EV-CATCHER assay to purify and release intact EVs produced by pCT-CD63-GFP transduced LM-3475 cells [Supplementary Figure 2] by measuring their uptake in vitro. When comparing the uptake of CD63-GFP EVs (i.e., produced by our LM-3475 cells) purified by ultracentrifugation or by our anti-human anti-CD63 EV-CATCHER by non-transduced LM-3475 cells, we similarly detected GFP labeled EVs inside treated cells using confocal microscopy [Supplementary Figure 2]. Prior to the purification of exhaled EVs, we also compared the species specificity of our anti-human and anti-mouse anti-CD63 antibodies by Western blot analyses of EVs ultracentrifuged from tissue culture-derived media of human MDA-MB-231 breast cancer cell, human HEK293 cells, and primary mouse bone marrow-derived endothelial cells (BMEC), which revealed high species-specific recognition of our anti-human and anti-mouse anti-CD63 antibodies [Figure 7A]. Considering the high tumor burden observed at 24 weeks (Supplementary Figure 5; see H&E), we chose to conduct our miRNA NGS analyses with EBC collected at weeks 20, 21, and 22 to ensure similar disease burden among the animals and high miRNA detectability. Prior to our analyses with NGS, we conducted species-specific sequential isolations of human and then mouse EVs from whole mouse EBC, using our respective anti-human and anti-mouse CD63-EV-CATCHER assays. Our NGS data of whole EBC (Figure 7B, blue and green squares) identified miRNAs unique to lung tumor-bearing animals compared to whole EBC of control mice (Figure 7B, red and green squares). Comparatively, when using our anti-human anti-CD63 EV-CATCHER to purify human tumor EVs from mouse EBC of lung tumor-bearing mice (Figure 7B, red and orange squares), we identified miRNAs, whose expression overlapped with those detected in whole EBC of lung tumor-bearing animals but not detected in control EBC (Figure 7B, blue and red squares). When using the anti-mouse anti-CD63 EV-CATCHER assay, we generated miRNA profiles (Figure 7B, blue and purple squares), which clustered closely to that of whole EBC from control mice (Figure 7B, blue and green squares). It is important to note that when using the anti-human anti-CD63 EV-CATCHER assay on EBC of control animals (Figure 7B, blue and orange squares) where no human EVs were anticipated to be present, due to the minimal cross-reactivity of the human anti-CD63 antibody against mouse CD63, we captured non-specific miRNA profiles that clustered between the miRNA profiles of whole EBC from control mice and mouse EVs purified with the anti-mouse anti-CD63 EV-CATCHER assay from control animals. As displayed in Supplementary Figure 6, the number of reads detected non-specifically (104 reads) was 1,000-fold lower than the signal detected specifically with human exh-EVs purified from EBC of lung tumor-bearing mice (107 reads). We noted that the non-specific capture of EVs using our anti-human anti-CD63 EV-CATCHER with EBC of control mice was ~10.5% (5.8% + 0.8% + 3.5% + 0.4%), or for 27 miRNAs that were unique to mouse whole EBC. However, we observed an overlap of 80.6% (69.3% + 3.5% + 5.8% + 1.2% + 0.4% + 0.4% or 207 miRNAs) of all 257 miRNAs reproducibly detected (i.e., with at least 5 reads in 6 out of 9 samples per group in 2 out of the three weeks) between whole EBC of lung tumor-bearing mice and human EVs purified from the EBC of lung tumor-bearing mice [Figure 7C]. These results confirmed that the bulk of differentially expressed miRNAs detectable in the EBC of lung tumor-bearing mice originates from human tumor exhaled EVs.

Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles

Figure 7. MiRNA analyses of EBC and exhaled EVs collected from control and lung tumor-bearing mice. (A) Western blot evaluation of anti-human and anti-mouse CD63 antibodies using EVs purified from tissue culture media of human breast cancer MDA-MB-231 cells, human kidney cancer HEK293 cells, and normal mouse bone marrow endothelial cells (BMECs); (B) Heatmap analysis of the top 142 most differentially detectable miRNAs between small-RNA extracted from whole EBC (green), and sequentially purified from human exhaled EVs using the anti-human anti-CD63 EV-CATCHER assay from whole EBC (orange), and mouse exhaled EVs using the anti-mouse anti-CD63 EV-CATCHER assay from the same whole EBC samples (purple), collected at weeks 21 (light grey), 22 (brown), and 23 (dark grey) from female control (blue) and lung tumor-bearing (red) mice detectable at study end (week 24). We conducted our analyses in triplicate (i.e., three repeats per RNA purification) on 9 control female mice and 9 lung tumor-bearing female mice. The EBC collected three times a week from the same 3 females was combined (~ 300 µL) to conduct the three different analyses (whole EBC, human exh-EVs, mouse exh-EVs) in triplicate [i.e., 3 sets of 3 EBC collections per control (n = 9) or lung tumor-bearing group (n = 9)]; (C) Venn Diagram displaying the overlap in the identity of the miRNAs detected between whole EBC of lung tumor-bearing mice (yellow), human exh-EVs in lung tumor-bearing mice (orange), mouse exh-EVs in control mice (purple), and human exh-EVs in controls mice (green, non-specific signal). The miRNAs that were selected for these analyses were detected by NGS but had at least 5 reads in 6 of the 9 samples analyzed and were reproducibly detected at least two of the three weeks (weeks 20, 21, and 22). The Venn diagram indicates that 21 miRNAs were non-specifically detected by use of the anti-human anti-CD63 EV-CATCHER assay with EBC of control mice and represented 9% of all selected miRNAs; (D) Small RNAs extracted from whole EBC samples collected at weeks 2, 6, and 11 were evaluated for expression of miR-222, miR-210, miR-374a, and miR-584 by TaqmanTM quantitative PCR analyses using the 2ΔΔCt method to evaluate fold change by comparison to the control sample at week 2. All 4 miRNAs were selected because they were found to be upregulated in the whole EBC of lung tumor-bearing mice compared to control mice by NGS analyses.

Feasibility of detecting differently expressed miRNAs in EBC by qPCR analyses

Next, we sought to retrospectively validate our findings by evaluating EBC samples collected at earlier stages of disease (i.e., weeks 2, 6, and 11) and to determine whether we could detect metastatic lung tumors non-invasively by simple qPCR analysis of differentially expressed miRNAs identified by our NGS analyses [Figure 7D]. As similarly observed with our NGS data obtained from condensates collected with our v1.0 collection system, we also found miR-222 and miR-210 to be increased in expression in whole EBC of lung tumor-bearing animals collected with our v2.0 collection system, compared to EBC of control mice. However, we also identified two additional miRNAs (miR-374a and miR-584) that were mostly detectable by our NGS analyses in whole EBC and human tumor EVs of lung tumor-bearing animals but not detected in EBC of controls. When reanalyzing NGS data obtained with condensates collected from control and lung tumor-bearing mice with our v1.0 collection system (see Figure 3C; see miR-374a and miR-584), we noted that although both miRNAs had lower reads, they appeared also to be uniquely upregulated in condensates of lung tumor-bearing mice. When we conducted our comparative qPCR analyses of EBC collected from control and lung tumor-bearing female mice, we reproducibly validated the upregulated expression of all miRNAs in EBC of lung tumor-bearing mice. However, we found that miR-222 and miR-374a provided greater sensitivity for earlier detection of disease (Figure 7D; at week 2) than miR-210 and miR-584 (Figure 7D; at week 6). These results further confirmed that exhaled metastatic human lung tumor EVs provide molecular surrogates for non-invasive early detection of secondary lung tumors in mice.

Proteomic analyses of EBC from individual animals

Finally, using our EV proteomic analytical approach described above, we sought to confirm whether the protein content of EBC collected with our v2.0 system for nose/mouth collection from single animals allowed for a more targeted capture of biological material of lung tissue or respiratory tissue origin. Our EBC proteomic analyses identified a total of 286 proteins that were common to control female mice [n = 3; 29 ng total protein input for mass spectrometry (MS)] and lung tumor-bearing female mice (n = 3; 38 ng total protein input for MS). Due to high sequence homology between human and mouse proteins, we could not determine the human tumor or mouse tissue contribution. However, our proteomic analyses of EBC from lung tumor-bearing mice identified 47 additional human proteins (a total of 333 proteins). When selecting the top 60 most differentially expressed EBC proteins that were common to control and lung tumor-bearing EBC [Supplementary Figure 7], we confirmed detection of several proteins that had been correlated with pro-metastatic properties, which were also upregulated in condensates collected from lung tumor-bearing mice with our v1.0 system, but that displayed even greater differential expression in EBC collected with our v2.0 system (i.e., Vimentin, α-enolase, integrin B1, Plectin)[100,106-107]. Finally, when we analyzed the most likely tissue distribution/origin of the common proteins detected the EBC of both groups, by using prominent tissue expression as determined with ProteinAtlas, we found that our v2.0 collection system generally enabled the collection of EBC with a higher proportion of proteins of lung and respiratory tissue origin [Figure 8]. These proteomic analyses illustrate that adding a nose/mouth collection device improved performance of our EBC collections as we observed its enrichment with proteins of respiratory tissue origin.

Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles

Figure 8. Proteomic analysis of EBC pooled from controls and lung tumor-bearing mice. Pie chart distribution of the 231 identified proteins stratified based on the preferential organ/tissue expression of each individual protein based on ProteinAtlas, and classified as either from lung, skin, urine, breast, testis, upper digestive tract, colon, and other undetermined tissue origins (i.e., Other).

DISCUSSION

In this proof-of-principle study, we investigated whether the analysis of exhaled condensates collected from an orthotopic animal model of secondary lung cancer would enable the non-invasive detection of lung tumors. Considering that we and others have previously demonstrated that miRNAs can be reproducibly detected in human exhaled breath condensates[43-47] and that they hold both diagnostic and prognostic potential for the detection of lung cancer, we developed collection systems and molecular assays to quantify them in mouse exhaled condensates.

In order to establish a baseline for the study of exhaled condensates from mice, we compared the collection and analysis of two types of condensates recovered from our mice using two different systems: one for the collection of condensates from unrestrained mice, freely roaming in a sealed glass chamber (v1.0 system), and one for the targeted capture of exhaled breath condensates directly from the nose/mouth of individually restrained animals (v2.0 system). Despite experimental and technical limitations due to the low volumes of condensate and EBC that were recovered with our v1.0 and v2.0 systems, respectively, we successfully conducted miRNA next-generation sequencing (NGS), qPCR validation, and used proteomic analyses to evaluate the condensates. Although our proteomic analyses yielded low outputs, we utilized our data to evaluate the potential origins of the proteins from condensate and EBC samples collected with our two different systems. Our results unequivocally demonstrated that human proteins can be specifically identified from condensates (i.e., 216 proteins) and EBC (i.e., 47 proteins) samples collected from lung tumor-bearing mice. However, when evaluating the putative tissue origin of proteins (n = 232) detected in condensates collected with our v1.0 system, which were common between control and lung tumor-bearing mice, we observed that a large proportion of them were associated with tissues/organs outside of the respiratory system (i.e., skin, urogenital (i.e., urine), reproductive (i.e., testis and breast), lower (i.e., the colon) and upper digestive tracts [i.e., esophagus and mouth)]. This suggested that the collection of condensates from free-roaming mice additionally gathered biological material from organs other than the respiratory system, which we anticipated would limit the discovery of exhaled human lung tumor proteins. Indeed, studies on metastatic breast cancer cell lines that were intentionally established to enhance metastatic colonization within the lungs upon inoculation into the circulatory system, demonstrated that some of these metastatic cells may colonize and expand as tumor foci in organs other than the lung[101,109,110].

Thus, to improve the collection of exhaled lung condensates, we developed our v2.0 system, where EBC was directly captured from the nose/mouth of our mice. Although we noted a significant decrease in the volume of biofluid collected with our v2.0 system (i.e., from ~63 µL for unrestrained animal pairs/h to ~29 µL per single restrained animal per 2 h), we observed an increase in proteins originating from the respiratory system relative to the v1.0 system. As anticipated with lower volumes and thus lower amounts of condensed biological material (< 40 ng input for MS), our proteomic analyses of EBC identified a lower number of proteins but demonstrated that proportionally to those detectable with the v1.0 system, putative respiratory proteins were enriched in EBC collected directly from the nose/mouth of our animals with the v2.0 system. Although the v1.0 collection system generally appeared to provide a condensate that was less clean than EBC (i.e., proteins originating from urine, skin, semen, etc.), we believe that it holds value for the collection of condensates in animal studies investigating advanced lung diseases or injuries, where immobilization or animal manipulation is restricted due to shallow breathing and/or the risk of stress-related death. For example, when investigating the continuum of dose-dependent injury and/or recovery after inhalation of highly toxic chemicals, such as sulfur mustard, the analysis of lung injuries in rats can only be performed by collection and analysis of bronchoalveolar lavages (BAL) and by pathological evaluation of lung tissues at either scheduled study termination (i.e., 30 days) or via a serial sacrifice experimental design[111]. In such instances, we would propose that regular and non-invasive collection of condensates may not only enable health monitoring by identification and quantification of important prognostic exhaled biomarkers but also serve to limit and reduce the numbers of animals otherwise necessary for a serial sacrifice approach. Together, our preliminary proteomic analyses substantially support the conclusion that condensates and EBC samples contain exhaled proteins of lung tissue and tumor origin. Future proteomic studies involving larger animal colonies and the collection of larger EBC volumes have the potential to enable unambiguous identification of exhaled tumor proteins or proteins from exhaled tumor EVs.

To date, only a small number of studies have been conducted on mouse exhaled breath that have evaluated the detection of exhaled biomarkers, which may be associated with asthma, non-cystic fibrosis bronchiectasis, and chlorine exposure[112-114]. However, to our knowledge, no studies have measured or detected miRNAs in exhaled condensates collected from mice. There have been studies conducted on BAL collected from mouse models of asthma, hyperoxia, and ARDS, which demonstrated that it is rich in miRNAs with potential diagnostic, prognostic, and therapeutic value, and that these miRNAs are contained in EVs originating not only from lung tissue but also from immune and blood cells[115-117]. Although a few human studies have suggested that EVs contained in the biofluid lining of the lungs can become aerosolized during normal tidal respiration and be purified from EBC, no studies have evaluated the presence of EVs in mouse EBC[118-119]. Thus, using nanoparticle and TEM analyses, we investigated and determined that the EBC of both control and lung tumor-bearing mice contains EVs. Interestingly, whereas a low number of EVs (65-150 nm) could be detected in the EBC collected from control animals (Supplementary Figure 8; n = 158 per ml of EBC), we found that this number was ~10-fold greater (Supplementary Figure 8; n = 1,450) - and even higher at later stages of disease - for EBC collected from lung tumor-bearing mice. Furthermore, when we used super-resolution nanoimaging, we were able to confirm that the EBC of human lung tumor-bearing mice contained human tumor-derived EVs (positive for CD9, CD63, and CD81). Although we could observe low levels of EVs by TEM in the EBC of control mice, due to the lack of a proper mouse EV validation assay, as per MISEV guidelines, we could not fully validate their identity as being murine cell-derived EVs. Based on our preliminary experiments, we conclude that such validating experiments can be performed but will require very high volumes of EBC (> 10 mL).

Since we determined that the EBC of lung tumor-bearing mice contained human tumor-derived EVs, we sought to evaluate their miRNA cargos and thus customized our EV-CATCHER assay with an anti-human anti-CD63 antibody, which we had previously tested for the purification of human EVs from human plasma and serum[97]. We experimentally confirmed the capture and release of intact CD63-GFP+ EVs produced in large amounts by our LM-3475 cells in vitro prior to purifying low abundance (i.e., compared to tissue culture) human tumor-derived EVs from the EBC of lung tumor-bearing mice. Our miRNA NGS analyses not only support the idea that human lung tumor-derived EV-miRNAs can reliably be detected and quantified in the EBC during tumor progression, but also that the bulk of the miRNA signal originates from exhaled human tumor-derived EVs. We wish to note that although we could non-specifically capture miRNA NGS profiles from the EBC of control mice using our anti-human anti-CD63 EV-CATCHER assay, these profiles only contained 10.5% of the detectable miRNAs with 1,000 times fewer miRNA reads compared to human tumor-derived EVs purified from the EBC of lung tumor-bearing mice. Once we reliably identified human tumor-derived EV-miRNAs consistently detectable at weeks 20, 21, and 22, using qPCR, we demonstrated that a select set of these miRNAs (i.e., miR-222, miR-210, miR-374a, miR-584) could reliably be detected as upregulated within 1-2 weeks post tail vein injection of the metastatic LM-3475 cell line. In contrast, and consistent with studies using other metastatic breast cancer cell lines[109,110], in vivo bioluminescent imaging of tumor cells appears significantly detectable 6 weeks after tail vein injection. Although our data suggests that qPCR detection of tumor-specific exhaled EV miRNAs may be more sensitive than bioluminescent imaging of lung tumors in animals (i.e., NGS and qPCR both have lower sensitivity thresholds than standard in vivo imaging techniques), further investigation on the sensitivity of this non-invasive detection is required. To date, only one micro-CT scanning mouse study has detected small lung tumors (i.e., as low as 15.4 % of lung volume) by imaging[120]. To determine the sensitivity of qPCR detection of early tumors and to determine whether our qPCR detects miRNAs from disseminated cells or from existing small tumor foci, future studies will need to compare micro-CT images of animals at 1-2 weeks post-tail vein injection with the corresponding qPCR signal[9].

Although we experimentally limited our molecular analyses on EBC collected from female mice, considering that breast cancer and secondary lung cancer following primary breast cancer are prevalent in females[108], our findings open a new avenue for the study of lung diseases in animal models, as the non-invasive collection and analysis of their EBC may facilitate the identification and quantification of exhaled miRNAs profiles associated with active, progressing, and/or exacerbated disease. We envision that expanding our approach to study human primary and other secondary lung cancers, in adequately powered animal studies, has the potential to identify relevant exhaled human EV biomarkers[121-125]. However, instead of using clonal cell lines, we propose that using patient-derived tumor cells in immuno-competent mice may help investigate the potential diagnostic and/or prognostic value of human-tumor exhaled EV miRNAs and other RNAs[126]. Furthermore, since EV-CATCHER can easily be customized to target surface markers of specific EV subpopulations, we foresee that using it to separate lung tumor cell-derived exhaled EVs from immune and innate cell-derived EVs may help further improve the selection of exhaled tumor EVs for the fine-tuned detection of different types of lung cancers. It is important to note that diet, inflammation, and other confounding factors associated with the environment may also be studied in lung cancer animal models to determine whether their effects on tumor growth may be non-invasively detectable in exhaled tumor EVs or exhaled EVs of different cellular origin (i.e., immune cells, lung cells).

Overall, our findings are highly clinically relevant, as the lung represents a central organ for the circulation of blood and is an opportunistic site for metastatic colonization of circulating tumor cells (CTCs), which can originate from several primary tumor organ sites that include breast, colorectal, head-and-neck, urogenital, gynecological and lymphatic cancers[127-132]. Considering that these biologically different cell types have the potential to colonize the lung, the analysis of EBC from lung tumor-bearing animal models established using metastatic cancer cells originating from different tissue types may help identify common metastatic miRNAs (e.g., the miR-200 metastatic cluster was detected in both our mouse EBC datasets) as well as primary tumor site-specific miRNAs, which may help with the development of molecular assays for early and non-invasive detection of metastatic lung disease. However, to determine its applicability to human EBC studies, careful evaluation of the type of EBC collection system, proper representation of lung cancer types and stages for adequate power analyses, and most importantly, evaluation of the reproducibility and sensitivity of the purification and quantification assays will be necessary to determine the usefulness of EBC and exhaled tumor EV biomarkers for the non-invasive detection of human lung cancers.

Limitations of the study

Although our study is novel and provides insights into the collection and analysis of exhaled tumor EVs from tumor-bearing animal models, we have identified several limitations that should be carefully considered when designing future studies. Particularly, we showed that our v2.0 system allowed for the collection of a low number of EVs from control animals, which limited subsequent analyses and molecular validations. Even though we had confirmed the specificity of our anti-human anti-CD63 EV-CATCHER assay, we determined that we could still capture non-specific miRNA signal, likely due to mouse anti-CD63 recognition. This indicates that to conduct species-specific EV purifications, additional anti-human anti-CD63 antibodies will have to be tested to guarantee sole purification of human tumor EVs from mouse EBC. Alternatively, we propose that a targeted anti-GFP EV-CATCHER assay, although not biologically relevant to EVs (i.e., not targeting common EV tetraspanins), could be used in future studies to increase specific selection of exhaled human tumor-derived EVs produced by CD63-GFP+ LM-3475 cells, along with GFP fluorescent signal detection to further confirm the identity and origin of CD63-GFP+ tumor EVs.

In sum, this study is the first of its kind and it unambiguously demonstrates that exhaled EVs and their miRNA cargos can be purified and quantified from the EBC of lung tumor-bearing animal models to detect aggressive secondary lung cancer of primary breast origin non-invasively.

DECLARATIONS

Acknowledgments

The authors would like to thank Mrs. Chelsea Doughty (MSc) for helping with the collection of exhaled breath condensates; Mr. Michael Berne from the TUFTS genomic core facility, Boston, MA, for the processing of the high-quality sequencing data, and Mrs. Leslie Cummins (MSc) from Albert Einstein College of Medicine, Bronx, NY for high-quality Transmission Electron Microscopy images. We would also like to thank Laura Ramkissoon at the Albert Einstein College of Medicine histology & comparative pathology core facility, Bronx, NY for the lung tissue sectioning and H&E Staining.

Authors' Contributions

Conceived the original ideas and designed the project: Loudig O, Mitchell MI

Performed all experiments with the help: Mitchell MI, Loudig O, Liu C, Donnelly K

Wrote the manuscript: Loudig O, Mitchell MI

Performed the bioinformatics analyses: Ben-Dov IZ, Wang T

Provided original LM-3475 cell line and assisted with project conceptualization: Hazan RB

Performed tdTomato-Luc transduction experiments: Zakrzewski J

Performed all proteomic experiments and analyses: Ma J

Be responsible for pathological evaluations: Chow K, Bauer TL

Reviewed and edited the manuscript: Loudig O, Mitchell MI, Ben-Dov IZ, Ma J, Hazan RB

Read and agreed to the published version of the manuscript: Mitchell MI, Ben-Dov IZ, Liu C, Wang T, Hazan RB, Bauer TL, Zakrzewski J, Donnelly K, Chow K, Ma J, Loudig O

Availability of Data and Materials

Data supporting the published data will be shared on reasonable requests.

Financial Support and Sponsorship

The histology reported in this publication was supported by the Montefiore Einstein Cancer Center Support Grant of the National Institutes of Health under award number P30CA013330; and the proteomics work performed by the Mass Spectrometry and Analytical Pharmacology Shared Resource is partially supported by NIH/NCI grant P30CA051008.

Conflicts of Interest

Olivier Loudig and Hackensack Meridian Health have private equity interests with the company EV Diagnostics, LLC. Olivier Loudig is also a Junior Editorial Board member of the journal Extracellular Vesicles and Circulating Nucleic Acids. The other authors declared that there are no conflicts of interest.

Ethical Approval and Consent to Participate

The Institutional Animal Care & Use Committee (IACUC) for the Center for Discovery and Innovation granted approval for all animal protocols performed in this project (approved protocol number 288.00.)

Consent for Publication

Not applicable.

Copyright

© The Author(s) 2024.

Supplementary Materials

REFERENCES

1. Sung H, Ferlay J, Siegel RL, et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 2021;71:209-49.

2. Siegel RL, Miller KD, Fuchs HE, Jemal A. Cancer statistics, 2021. CA Cancer J Clin 2021;71:7-33.

3. Stella GM, Kolling S, Benvenuti S, Bortolotto C. Lung-seeking metastases. Cancers 2019;11:1010.

4. Caparica R, Mak MP, Rocha CH, et al. Pulmonary nodules in patients with nonpulmonary cancer: not always metastases. J Glob Oncol 2016;2:138-44.

5. Chen H, Stoltzfus KC, Lehrer EJ, et al. The epidemiology of lung metastases. Front Med 2021;8:723396.

6. Ha D, Choi H, Chevalier C, Zell K, Wang XF, Mazzone PJ. Survival in patients with metachronous second primary lung cancer. Ann Am Thorac Soc 2015;12:79-84.

7. Jamil A. and Kasi A. Lung metastasis. Available from: https://www.ncbi.nlm.nih.gov/books/NBK553111/ [Last accessed on 27 Mar 2024].

8. Wang R, Yin Z, Liu L, et al. Second primary lung cancer after breast cancer: a population-based study of 6,269 women. Front Oncol 2018;8:427.

9. Medeiros B, Allan AL. Molecular mechanisms of breast cancer metastasis to the lung: clinical and experimental perspectives. Int J Mol Sci 2019;20:2272.

10. Mangiameli G, Cioffi U, Alloisio M, Testori A. Lung metastases: current surgical indications and new perspectives. Front Surg 2022;9:884915.

11. Antonoff MB, Sofocleous CT, Callstrom MR, Nguyen QN. The roles of surgery, stereotactic radiation, and ablation for treatment of pulmonary metastases. J Thorac Cardiovasc Surg 2022;163:495-502.

12. Dama E, Colangelo T, Fina E, et al. Biomarkers and lung cancer early detection: state of the art. Cancers 2021;13:3919.

13. Haranguș A, Berindan-Neagoe I, Todea DA, Șimon I, Șimon M. Noncoding RNAs and liquid biopsy in lung cancer: a literature review. Diagnostics 2019;9:216.

14. de Fraipont F, Gazzeri S, Cho WC, Eymin B. Circular RNAs and RNA splice variants as biomarkers for prognosis and therapeutic response in the liquid biopsies of lung cancer patients. Front Genet 2019;10:390.

15. Zhong S, Golpon H, Zardo P, Borlak J. miRNAs in lung cancer. a systematic review identifies predictive and prognostic miRNA candidates for precision medicine in lung cancer. Transl Res 2021;230:164-96.

16. Patel U, Susman D, Allan AL. Influence of extracellular vesicles on lung stromal cells during breast cancer metastasis. Int J Mol Sci 2023;24:11801.

17. Hinestrosa JP, Kurzrock R, Lewis JM, et al. Early-stage multi-cancer detection using an extracellular vesicle protein-based blood test. Commun Med 2022;2:29.

18. Liu Z, Kong Y, Dang Q, et al. Liquid biopsy in pre-metastatic niche: from molecular mechanism to clinical application. Front Immunol 2022;13:958360.

19. Habli Z, AlChamaa W, Saab R, Kadara H, Khraiche ML. Circulating tumor cell detection technologies and clinical utility: challenges and opportunities. Cancers 2020;12:1930.

20. Agashe R, Kurzrock R. Circulating tumor cells: from the laboratory to the cancer clinic. Cancers 2020;12:2361.

21. Pantel K, Alix-Panabières C. Circulating tumour cells in cancer patients: challenges and perspectives. Trends Mol Med 2010;16:398-406.

22. Riethdorf S, Fritsche H, Müller V, et al. Detection of circulating tumor cells in peripheral blood of patients with metastatic breast cancer: a validation study of the CellSearch system. Clin Cancer Res 2007;13:920-8.

23. Seijo LM, Peled N, Ajona D, et al. Biomarkers in lung cancer screening: achievements, promises, and challenges. J Thorac Oncol 2019;14:343-57.

24. Yendamuri S, Vaporciyan AA, Zaidi T, et al. 3p and 10q deletions detected by fluorescence in situ hybridization (FISH): A potential new tool for early detection of non-small cell lung cancer (NSCLC). J Clin Oncol 2007;25:7606.

25. Chen CC, Bai CH, Lee KY, Chou YT, Pan ST, Wang YH. Evaluation of the diagnostic accuracy of bronchial brushing cytology in lung cancer: A meta-analysis. Cancer Cytopathol 2021;129:739-49.

26. Pavel AB, Campbell JD, Liu G, et al. AEGIS Study Team. Alterations in bronchial airway miRNA expression for lung cancer detection. Cancer Prev Res 2017;10:651-9.

27. Matthiesen R. MS-based biomarker discovery in bronchoalveolar lavage fluid for lung cancer. Proteomics Clin Appl 2020;14:e1900077.

28. Engel E, Schmidt B, Carstensen T, et al. Detection of tumor-specific mRNA in cell-free bronchial lavage supernatant in patients with lung cancer. Ann N Y Acad Sci 2004;1022:140-6.

29. Anglim PP, Alonzo TA, Laird-Offringa IA. DNA methylation-based biomarkers for early detection of non-small cell lung cancer: an update. Mol Cancer 2008;7:81.

30. Schmidt B, Rehbein G, Fleischhacker M. Liquid profiling in lung cancer - quantification of extracellular mirnas in bronchial lavage. In: Gahan PB, Fleischhacker M, Schmidt B, editors. Circulating Nucleic Acids in Serum and Plasma - CNAPS IX. Cham: Springer International Publishing; 2016. pp. 33-7.

31. Mutlu GM, Garey KW, Robbins RA, Danziger LH, Rubinstein I. Collection and analysis of exhaled breath condensate in humans. Am J Respir Crit Care Med 2001;164:731-7.

32. Keogh RJ, Riches JC. The use of breath analysis in the management of lung cancer: is it ready for primetime? Curr Oncol 2022;29:7355-78.

33. Wang P, Huang Q, Meng S, et al. Identification of lung cancer breath biomarkers based on perioperative breathomics testing: a prospective observational study. EClinicalMedicine 2022;47:101384.

34. van der Schee M, Pinheiro H, Gaude E, et al. Breath biopsy for early detection and precision medicine in cancer. Ecancermedicalscience 2018;12:ed84.

35. Marzorati D, Mainardi L, Sedda G, Gasparri R, Spaggiari L, Cerveri P. A review of exhaled breath: a key role in lung cancer diagnosis. J Breath Res 2019;13:034001.

36. Jia Z, Patra A, Kutty VK, Venkatesan T. Critical review of volatile organic compound analysis in breath and in vitro cell culture for detection of lung cancer. Metabolites 2019;9:52.

37. Kubáň P, Foret F. Exhaled breath condensate: determination of non-volatile compounds and their potential for clinical diagnosis and monitoring. A review. Anal Chim Acta 2013;805:1-18.

38. Rahimpour E, Khoubnasabjafari M, Jouyban-Gharamaleki V, Jouyban A. Non-volatile compounds in exhaled breath condensate: review of methodological aspects. Anal Bioanal Chem 2018;410:6411-40.

39. Campanella A, De Summa S, Tommasi S. Exhaled breath condensate biomarkers for lung cancer. J Breath Res 2019;13:044002.

40. Effros RM, Peterson B, Casaburi R, et al. Epithelial lining fluid solute concentrations in chronic obstructive lung disease patients and normal subjects. J Appl Physiol 2005;99:1286-92.

41. Horváth I, Hunt J, Barnes PJ, et al. ATS/ERS Task Force on Exhaled Breath Condensate. Exhaled breath condensate: methodological recommendations and unresolved questions. Eur Respir J 2005;26:523-48.

42. Kuo TC, Tan CE, Wang SY, et al. Human breathomics database. Database 2020;2020:baz139.

43. Shi M, Han W, Loudig O, et al. Initial development and testing of an exhaled microRNA detection strategy for lung cancer case-control discrimination. Sci Rep 2023;13:6620.

44. Pinkerton M, Chinchilli V, Banta E, et al. Differential expression of microRNAs in exhaled breath condensates of patients with asthma, patients with chronic obstructive pulmonary disease, and healthy adults. J Allergy Clin Immunol 2013;132:217-9.

45. Pérez-Sánchez C, Barbarroja N, Pantaleão LC, et al. Clinical utility of microRNAs in exhaled breath condensate as biomarkers for lung cancer. J Pers Med 2021;11:111.

46. Mendes FC, Paciência I, Ferreira AC, et al. Development and validation of exhaled breath condensate microRNAs to identify and endotype asthma in children. PLoS One 2019;14:e0224983.

47. Faversani A, Favero C, Dioni L, et al. An EBC/Plasma miRNA signature discriminates lung adenocarcinomas from pleural mesothelioma and healthy controls. Front Oncol 2021;11:643280.

48. Lucchetti D, Santini G, Perelli L, et al. Detection and characterisation of extracellular vesicles in exhaled breath condensate and sputum of COPD and severe asthma patients. Eur Respir J 2021;58:2003024.

49. Dobhal G, Datta A, Ayupova D, Teesdale-Spittle P, Goreham RV. Isolation, characterisation and detection of breath-derived extracellular vesicles. Sci Rep 2020;10:17381.

50. Sinha A, Yadav AK, Chakraborty S, et al. Exosome-enclosed microRNAs in exhaled breath hold potential for biomarker discovery in patients with pulmonary diseases. J Allergy Clin Immunol 2013;132:219-22.

51. O'Brien J, Hayder H, Zayed Y, Peng C. Overview of MicroRNA biogenesis, mechanisms of actions, and circulation. Front Endocrinol 2018;9:402.

52. Ketting RF. microRNA Biogenesis and Function. In: Großhans H, editor. Regulation of microRNAs. New York: Springer US; 2010. pp. 1-14.

53. Ardekani AM, Naeini MM. The role of MicroRNAs in human diseases. Avicenna J Med Biotechnol 2010;2:161-79.

54. Acunzo M, Romano G, Wernicke D, Croce CM. MicroRNA and cancer--a brief overview. Adv Biol Regul 2015;57:1-9.

55. Santos RM, Moreno C, Zhang WC. Non-coding RNAs in lung tumor initiation and progression. Int J Mol Sci 2020;21:2774.

56. Rohan TE, Wang T, Weinmann S, et al. A miRNA expression signature in breast tumor tissue is associated with risk of distant metastasis. Cancer Res 2019;79:1705-13.

57. Yanaihara N, Caplen N, Bowman E, et al. Unique microRNA molecular profiles in lung cancer diagnosis and prognosis. Cancer Cell 2006;9:189-98.

58. Zhu X, Kudo M, Huang X, et al. Frontiers of MicroRNA signature in non-small cell lung cancer. Front Cell Dev Biol 2021;9:643942.

59. Chakrabortty A, Patton DJ, Smith BF, Agarwal P. miRNAs: Potential as biomarkers and therapeutic targets for cancer. Genes 2023;14:1375.

60. Ware AP, Kabekkodu SP, Chawla A, Paul B, Satyamoorthy K. Diagnostic and prognostic potential clustered miRNAs in bladder cancer. 3 Biotech 2022;12:173.

61. Mao S, Lu Z, Zheng S, et al. Exosomal miR-141 promotes tumor angiogenesis via KLF12 in small cell lung cancer. J Exp Clin Cancer Res 2020;39:193.

62. Quirico L, Orso F. The power of microRNAs as diagnostic and prognostic biomarkers in liquid biopsies. Cancer Drug Resist 2020;3:117-39.

63. Théry C, Zitvogel L, Amigorena S. Exosomes: composition, biogenesis and function. Nat Rev Immunol 2002;2:569-79.

64. Pitt JM, Kroemer G, Zitvogel L. Extracellular vesicles: masters of intercellular communication and potential clinical interventions. J Clin Invest 2016;126:1139-43.

65. Mitchell MI, Loudig O. Communicator extraordinaire: extracellular vesicles in the tumor microenvironment are essential local and long-distance mediators of cancer metastasis. Biomedicines 2023;11:2534.

66. Brena D, Huang MB, Bond V. Extracellular vesicle-mediated transport: Reprogramming a tumor microenvironment conducive with breast cancer progression and metastasis. Transl Oncol 2022;15:101286.

67. Ozawa PMM, Alkhilaiwi F, Cavalli IJ, Malheiros D, de Souza Fonseca Ribeiro EM, Cavalli LR. Extracellular vesicles from triple-negative breast cancer cells promote proliferation and drug resistance in non-tumorigenic breast cells. Breast Cancer Res Treat 2018;172:713-23.

68. He S, Li Z, Yu Y, et al. Exosomal miR-499a-5p promotes cell proliferation, migration and EMT via mTOR signaling pathway in lung adenocarcinoma. Exp Cell Res 2019;379:203-13.

69. Yang M, Xiao R, Wang X, et al. MiR-93-5p regulates tumorigenesis and tumor immunity by targeting PD-L1/CCND1 in breast cancer. Ann Transl Med 2022;10:203.

70. Fabbri M, Paone A, Calore F, et al. MicroRNAs bind to Toll-like receptors to induce prometastatic inflammatory response. Proc Natl Acad Sci U S A 2012;109:E2110-6.

71. Wong GL, Abu Jalboush S, Lo HW. Exosomal MicroRNAs and organotropism in breast cancer metastasis. Cancers 2020;12:1827.

72. Zeng Z, Li Y, Pan Y, et al. Cancer-derived exosomal miR-25-3p promotes pre-metastatic niche formation by inducing vascular permeability and angiogenesis. Nat Commun 2018;9:5395.

73. Zhong Y, Ding X, Bian Y, et al. Discovery and validation of extracellular vesicle-associated miRNAs as noninvasive detection biomarkers for early-stage non-small-cell lung cancer. Mol Oncol 2021;15:2439-52.

74. Gao S, Guo W, Liu T, et al. Plasma extracellular vesicle microRNA profiling and the identification of a diagnostic signature for stage I lung adenocarcinoma. Cancer Sci 2022;113:648-59.

75. Wortzel I, Dror S, Kenific CM, Lyden D. Exosome-mediated metastasis: communication from a distance. Dev Cell 2019;49:347-60.

76. Mitchell MI, Ma J, Carter CL, Loudig O. Circulating exosome cargoes contain functionally diverse cancer biomarkers: from biogenesis and function to purification and potential translational utility. Cancers 2022;14:3350.

77. Couch Y, Buzàs EI, Di Vizio D, et al. A brief history of nearly EV-erything - The rise and rise of extracellular vesicles. J Extracell Vesicles 2021;10:e12144.

78. Logozzi M, Angelini DF, Giuliani A, et al. Increased plasmatic levels of PSA-expressing exosomes distinguish prostate cancer patients from benign prostatic hyperplasia: a prospective study. Cancers 2019;11:1449.

79. Newman LA, Useckaite Z, Johnson J, Sorich MJ, Hopkins AM, Rowland A. Selective isolation of liver-derived extracellular vesicles redefines performance of miRNA biomarkers for non-alcoholic fatty liver disease. Biomedicines 2022;10:195.

80. Chiasserini D, van Weering JR, Piersma SR, et al. Proteomic analysis of cerebrospinal fluid extracellular vesicles: a comprehensive dataset. J Proteomics 2014;106:191-204.

81. Choudhary I, Vo T, Paudel K, et al. Vesicular and extravesicular protein analyses from the airspaces of ozone-exposed mice revealed signatures associated with mucoinflammatory lung disease. Sci Rep 2021;11:23203.

82. Mimmi S, Zimbo AM, Rotundo S, et al. SARS CoV-2 spike protein-guided exosome isolation facilitates detection of potential miRNA biomarkers in COVID-19 infections. Clin Chem Lab Med 2023;61:1518-24.

83. Miranda J, Paules C, Nair S, et al. Placental exosomes profile in maternal and fetal circulation in intrauterine growth restriction - Liquid biopsies to monitoring fetal growth. Placenta 2018;64:34-43.

84. Than UTT, Guanzon D, Broadbent JA, Parker TJ, Leavesley DI. Deep sequencing micrornas from extracellular membrane vesicles revealed the association of the vesicle cargo with cellular origin. Int J Mol Sci 2020;21:1141.

85. Yu H, Guan Z, Cuk K, Brenner H, Zhang Y. Circulating microRNA biomarkers for lung cancer detection in Western populations. Cancer Med 2018;7:4849-62.

86. Asakura K, Kadota T, Matsuzaki J, et al. A miRNA-based diagnostic model predicts resectable lung cancer in humans with high accuracy. Commun Biol 2020;3:134.

87. Vykoukal J, Fahrmann JF, Patel N, et al. Contributions of circulating microRNAs for early detection of lung cancer. Cancers 2022;14:4221.

88. Wang X, Tian L, Lu J, Ng IO. Exosomes and cancer - diagnostic and prognostic biomarkers and therapeutic vehicle. Oncogenesis 2022;11:54.

89. He X, Park S, Chen Y, Lee H. Extracellular vesicle-associated miRNAs as a biomarker for lung cancer in liquid biopsy. Front Mol Biosci 2021;8:630718.

90. Zhang C, Yang J, Chen Y, et al. miRNAs derived from plasma small extracellular vesicles predict organo-tropic metastasis of gastric cancer. Gastric Cancer 2022;25:360-74.

91. Geng N, Qi Y, Qin W, et al. Two microRNAs of plasma-derived small extracellular vesicles as biomarkers for metastatic non-small cell lung cancer. BMC Pulm Med 2023;23:259.

92. Tanaka R, Yoshinouchi S, Karouji K, et al. A mouse model of lung cancer induced via intranasal injection for anticancer drug screening and evaluation of pathology. FEBS Open Bio 2023;13:51-9.

93. Kang Y, Omura M, Suzuki A, et al. Proliferation of human lung cancer in an orthotopic transplantation mouse model. Exp Ther Med 2010;1:471-5.

94. Madero-Visbal RA, Colon JF, Hernandez IC, et al. Bioluminescence imaging correlates with tumor progression in an orthotopic mouse model of lung cancer. Surg Oncol 2012;21:23-9.

95. Stevens LE, Arnal-Estapé A, Nguyen DX. Pre-conditioning the airways of mice with bleomycin increases the efficiency of orthotopic lung cancer cell engraftment. J Vis Exp 2018;136:56650.

96. Liu Y, Hou Y, Hua Y, Gao Y. A device to collect exhaled breath to study biomarkers in small animal models. Available from: https://www.biorxiv.org/content/10.1101/511931v1.full.pdf+html [Last accessed on 28 Mar 2024].

97. Mitchell MI, Ben-Dov IZ, Liu C, et al. Extracellular vesicle capture by AnTibody of CHoice and enzymatic release (EV-CATCHER): a customizable purification assay designed for small-RNA biomarker identification and evaluation of circulating small-EVs. J Extracell Vesicles 2021;10:e12110.

98. Loudig O, Liu C, Rohan T, Ben-Dov IZ. Retrospective MicroRNA sequencing: complementary DNA library preparation protocol using formalin-fixed paraffin-embedded RNA specimens. J Vis Exp 2018;135:57471.

99. Mensà E, Giuliani A, Matacchione G, et al. Circulating miR-146a in healthy aging and type 2 diabetes: age- and gender-specific trajectories. Mech Ageing Dev 2019;180:1-10.

100. Wu C, Zhou S, Mitchell MI, et al. Coupling suspension trapping-based sample preparation and data-independent acquisition mass spectrometry for sensitive exosomal proteomic analysis. Anal Bioanal Chem 2022;414:2585-95.

101. Minn AJ, Gupta GP, Siegel PM, et al. Genes that mediate breast cancer metastasis to lung. Nature 2005;436:518-24.

102. Agiostratidou G, Li M, Suyama K, et al. Loss of retinal cadherin facilitates mammary tumor progression and metastasis. Cancer Res 2009;69:5030-8.

103. Kim S, Yao J, Suyama K, et al. Slug promotes survival during metastasis through suppression of Puma-mediated apoptosis. Cancer Res 2014;74:3695-706.

104. Fan J, Xu G, Chang Z, Zhu L, Yao J. miR-210 transferred by lung cancer cell-derived exosomes may act as proangiogenic factor in cancer-associated fibroblasts by modulating JAK2/STAT3 pathway. Clin Sci 2020;134:807-25.

105. Ding J, Xu Z, Zhang Y, et al. Exosome-mediated miR-222 transferring: an insight into NF-κB-mediated breast cancer metastasis. Exp Cell Res 2018;369:129-38.

106. Perez SM, Brinton LT, Kelly KA. Plectin in cancer: from biomarker to therapeutic target. Cells 2021;10:2246.

107. Fei F, Qu J, Zhang M, Li Y, Zhang S. S100A4 in cancer progression and metastasis: a systematic review. Oncotarget 2017;8:73219-39.

108. Zheng G, Leone JP. Male breast cancer: an updated review of epidemiology, clinicopathology, and treatment. J Oncol 2022;2022:1734049.

109. Serganova I, Moroz E, Vider J, et al. Multimodality imaging of TGFbeta signaling in breast cancer metastases. FASEB J 2009;23:2662-72.

110. Jenkins DE, Hornig YS, Oei Y, Dusich J, Purchio T. Bioluminescent human breast cancer cell lines that permit rapid and sensitive in vivo detection of mammary tumors and multiple metastases in immune deficient mice. Breast Cancer Res 2005;7:R444-54.

111. Perry MR, Neal M, Hawks R, et al. A novel sulfur mustard (HD) vapor inhalation exposure model of pulmonary toxicity for the efficacy evaluation of candidate medical countermeasures. Inhal Toxicol 2021;33:221-33.

112. Neuhaus S, Seifert L, Vautz W, Nolte J, Bufe A, Peters M. Comparison of metabolites in exhaled breath and bronchoalveolar lavage fluid samples in a mouse model of asthma. J Appl Physiol 2011;111:1088-95.

113. Jonasson S, Magnusson R, Wingfors H, et al. Potential exhaled breath biomarkers identified in chlorine-exposed mice. J Anal Toxicol 2024;48:171-9.

114. Paris D, Palomba L, Mirra V, et al. NMR profiling of exhaled breath condensate defines different metabolic phenotypes of non-cystic fibrosis bronchiectasis. Int J Mol Sci 2020;21:8600.

115. Kulshreshtha A, Ahmad T, Agrawal A, Ghosh B. Proinflammatory role of epithelial cell-derived exosomes in allergic airway inflammation. J Allergy Clin Immunol 2013;131:1194-203, 1203.e1-14.

116. Lee H, Zhang D, Zhu Z, Dela Cruz CS, Jin Y. Epithelial cell-derived microvesicles activate macrophages and promote inflammation via microvesicle-containing microRNAs. Sci Rep 2016;6:35250.

117. Shikano S, Gon Y, Maruoka S, et al. Increased extracellular vesicle miRNA-466 family in the bronchoalveolar lavage fluid as a precipitating factor of ARDS. BMC Pulm Med 2019;19:110.

118. Stachowiak Z, Wojsyk-Banaszak I, Jończyk-Potoczna K, Narożna B, Langwiński W, Szczepankiewicz A. Extracellular vesicles-derived miRNAs as mediators of pulmonary exacerbation in pediatric cystic fibrosis. J Breath Res 2023;17:026005.

119. An J, McDowell A, Kim YK, Kim TB. Extracellular vesicle-derived microbiome obtained from exhaled breath condensate in patients with asthma. Ann Allergy Asthma Immunol 2021;126:729-31.

120. Bidola P, Martins de Souza E Silva J, Achterhold K, et al. A step towards valid detection and quantification of lung cancer volume in experimental mice with contrast agent-based X-ray microtomography. Sci Rep 2019;9:1325.

121. Drosten M, Guerra C, Barbacid M. Genetically engineered mouse models of k-ras-driven lung and pancreatic tumors: validation of therapeutic targets. Cold Spring Harb Perspect Med 2018;8:a031542.

122. Fitzgerald B, Connolly KA, Cui C, et al. A mouse model for the study of anti-tumor T cell responses in Kras-driven lung adenocarcinoma. Cell Rep Methods 2021;1:100080.

123. Foggetti G, Li C, Cai H, et al. Genetic determinants of EGFR-driven lung cancer growth and therapeutic response in vivo. Cancer Discov 2021;11:1736-53.

124. Politi K, Fan PD, Shen R, Zakowski M, Varmus H. Erlotinib resistance in mouse models of epidermal growth factor receptor-induced lung adenocarcinoma. Dis Model Mech 2010;3:111-9.

125. Ramelow J, Brooks CD, Gao L, et al. The oncogenic potential of a mutant TP53 gene explored in two spontaneous lung cancer mice models. BMC Cancer 2020;20:738.

126. Abdolahi S, Ghazvinian Z, Muhammadnejad S, Saleh M, Asadzadeh Aghdaei H, Baghaei K. Patient-derived xenograft (PDX) models, applications and challenges in cancer research. J Transl Med 2022;20:206.

127. Chiappetta M, Salvatore L, Congedo MT, et al. Management of single pulmonary metastases from colorectal cancer: state of the art. World J Gastrointest Oncol 2022;14:820-32.

128. Jin L, Han B, Siegel E, Cui Y, Giuliano A, Cui X. Breast cancer lung metastasis: Molecular biology and therapeutic implications. Cancer Biol Ther 2018;19:858-68.

129. Tyagi A, Sharma S, Wu K, et al. Nicotine promotes breast cancer metastasis by stimulating N2 neutrophils and generating pre-metastatic niche in lung. Nat Commun 2021;12:474.

130. Patel HD, Singla N, Ghandour RA, et al. Site of extranodal metastasis impacts survival in patients with testicular germ cell tumors. Cancer 2019;125:3947-52.

131. Zhang J, Kulkarni HR, Singh A, Baum RP. Complete regression of lung metastases in a patient with metastatic castration-resistant prostate cancer using 177Lu-PSMA radioligand therapy. Clin Nucl Med 2020;45:e48-50.

132. Gardner AB, Charo LM, Mann AK, Kapp DS, Eskander RN, Chan JK. Ovarian, uterine, and cervical cancer patients with distant metastases at diagnosis: most common locations and outcomes. Clin Exp Metastasis 2020;37:107-13.

Cite This Article

Original Article
Open Access
Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles
Megan I. Mitchell, ... Olivier Loudig

How to Cite

Mitchell, M. I.; Ben-Dov I. Z.; Liu C.; Wang T.; Hazan R. B.; Bauer T. L.; Zakrzewski J.; Donnelly K.; Chow K.; Ma J.; Loudig O. Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles. Extracell. Vesicles. Circ. Nucleic. Acids. 2024, 5, 138-64. http://dx.doi.org/10.20517/evcna.2023.77

Download Citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click on download.

Export Citation File:

Type of Import

Tips on Downloading Citation

This feature enables you to download the bibliographic information (also called citation data, header data, or metadata) for the articles on our site.

Citation Manager File Format

Use the radio buttons to choose how to format the bibliographic data you're harvesting. Several citation manager formats are available, including EndNote and BibTex.

Type of Import

If you have citation management software installed on your computer your Web browser should be able to import metadata directly into your reference database.

Direct Import: When the Direct Import option is selected (the default state), a dialogue box will give you the option to Save or Open the downloaded citation data. Choosing Open will either launch your citation manager or give you a choice of applications with which to use the metadata. The Save option saves the file locally for later use.

Indirect Import: When the Indirect Import option is selected, the metadata is displayed and may be copied and pasted as needed.

About This Article

Special Issue

© The Author(s) 2024. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, sharing, adaptation, distribution and reproduction in any medium or format, for any purpose, even commercially, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Data & Comments

Data

Views
933
Downloads
201
Citations
1
Comments
0
7

Comments

Comments must be written in English. Spam, offensive content, impersonation, and private information will not be permitted. If any comment is reported and identified as inappropriate content by OAE staff, the comment will be removed without notice. If you have any queries or need any help, please contact us at support@oaepublish.com.

0
Download PDF
Share This Article
Scan the QR code for reading!
See Updates
Contents
Figures
Related
Extracellular Vesicles and Circulating Nucleic Acids
ISSN 2767-6641 (Online)
Follow Us

Portico

All published articles are preserved here permanently:

https://www.portico.org/publishers/oae/

Portico

All published articles are preserved here permanently:

https://www.portico.org/publishers/oae/