fig9

High-voltage flat-tubular segment-in-series SOFCs: strategic design of an SrZrO<sub>3</sub> insulation layer

Figure 9. Output performance and post-operation characterization of the 12-cell FT-SIS-SOFC. (A) I-V-P curves; (B) impedance spectra; (C) fitted resistance components at different temperatures; (D) photographs of the FT-SIS-SOFC before testing, during high-temperature operation, and after testing, taken by the authors; (E) EDS elemental mapping after operation; and (F) cross-sectional SEM image of a repeating unit. The reported power densities were normalized to the total effective active area of the 12 cells (24 cm2). FT-SIS-SOFC: Flat-tubular segment-in-series solid oxide fuel cell; SZO: SrZrO3; EDS: energy-dispersive X-ray spectroscopy; SEM: scanning electron microscopy; I-V-P: current-voltage-power density curves.