Figure 4. Results of calibration represented as sampling rates compared with octanol-air partition coefficients for each individual compound for (A) double bowl; (B) single bowl; (C) no bowl configurations. The points in yellow indicate compounds for which a valid sampling rate could be calculated according to the defined criteria. Compounds for which no valid sampling rate could be calculated are indicated by their logKOA along the lower x-axis, color-coded according to the criteria which prohibited a valid sampling rate from being determined. The dashed green lines show the median sampling rate for each configuration. Three points with outlying sampling rates are omitted from the figures: sampling rates of 13.8 m3/day for BEH-TEBP in the single bowl configuration, 15.7 m3/day for BDE-100 in the single bowl configuration, and 9.38 m3/day for BDE-100 in the no bowl configuration.