Drains are traditionally used in a variety of surgical procedures;[1,2] although there is limited evidence of their usefulness.[3] Drains are classified based on various characteristics: as open or closed systems, as active versus passive, as prophylactic versus therapeutic; or by composition (e.g., polyurethane, silicone, or rubber).[2,4] Closed vacuum drains apply negative suction (60-80 kPa) in a sealed environment.[5] Drains are often secured using a single suture or adhesive tape to prevent inadvertent removal. Complications from drains include pain, hemorrhage, drain entrapment, and retrograde bacterial migration that can result in postoperative infections.[1,2]
We routinely use drains after flap reconstructions. For example, we place two or three vacuum suction drains in the gluteal myocutaneous rotation flaps that are used to cover sacral pressure sores. The drains are sutured for security and are completely removed if drainage is less than 30 mL/day.[1,2] If fluid production from the wound exceeds 30 mL/day for 5 days and is serous in nature, we progressively remove the drain in 3 cm steps until removal is complete.
The present report describes a method of progressive removal of an external drain without suture release. Specifically, we suture a loop through the skin and fix the drain by a double-loop through the first loop. One or two additional loops can be added if necessary. The suture is tied with multiple knots, and a simple dressing over the drain is used for wound closure.
For drain withdrawal, the drain suture is soaked with disinfectant spray (Bode Cutasept®F, Hamburg, Germany), to facilitate passage of the drain. The vacuum is then released to prevent the drain from adhering to the tissue. The forceps are positioned directly proximal to the securing suture and closed firmly. The drain is compressed and slid through the suture with gentle traction. If toothed forceps are used, the drain must be positioned proximal to the teeth to avoid tearing. This technique is applicable to drains of various diameters and materials.
We have used this technique to gradually extract drains during seven years of high-volume plastic surgery [Figure 1]. Our patients have reported no discomfort or pain. The technique is safe and useful in situations where gradual drain withdrawal is advantageous, such as high-output seromas, postflap harvests, and groin dissections. It avoids the need for re-suturing and permits healing from the wound base. This method requires a certain level of training and caution when performing the retrieval. The drain’s security must be checked after each withdrawal as it can loosen, resulting in premature drain removal.
Figure 1. Progressive drain removal without suture release. Gentle traction on the drain with the forceps in place permits withdrawal of drain
Financial support and sponsorship
Nil.
Conflicts of interest
There are no conflicts of interest.
REFERENCES
1. Dower R, Turner ML. Pilot study of timing of biofilm formation on closed suction wound drains. Plast Reconstr Surg 2012;130:1141-6.
3. Kosins AM, Scholz T, Cetinkaya M, Evans GR. Evidence-based value of subcutaneous surgical wound drainage: the largest systematic review and meta-analysis. Plast Reconstr Surg 2013;132:443-50.
Cite This Article

How to Cite
Jandali, Z.; Loh, C. Y. Y.; Thanassi, A. Progressive drain withdrawal without suture removal: a technical note. Plast. Aesthet. Res. 2014, 1, 41-2. http://dx.doi.org/10.4103/2347-9264.135564
Download Citation
Export Citation File:
Type of Import
Tips on Downloading Citation
Citation Manager File Format
Type of Import
Direct Import: When the Direct Import option is selected (the default state), a dialogue box will give you the option to Save or Open the downloaded citation data. Choosing Open will either launch your citation manager or give you a choice of applications with which to use the metadata. The Save option saves the file locally for later use.
Indirect Import: When the Indirect Import option is selected, the metadata is displayed and may be copied and pasted as needed.
About This Article
Copyright
Data & Comments
Data

Comments
Comments must be written in English. Spam, offensive content, impersonation, and private information will not be permitted. If any comment is reported and identified as inappropriate content by OAE staff, the comment will be removed without notice. If you have any queries or need any help, please contact us at [email protected].